Diagnostic Method
When the brake pedal is not depressed, the servo pressure sensor output value is -0.63 MPa or less or 1.53 MPa or more.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Reaction pressure | Less than -0.63 MPa or Exceeds 1.53 MPa |
Time needed for diagnosis: 3 s
Malfunction indicator light illumination: Illuminates as soon as a malfunction occurs.