DTC B1456: Outdoor Condenser Exit Temperature Sensor Circuit Open
DTC detecting condition:
When Exterior condenser outlet temperature sensor circuit is open.
Trouble symptom:
Compressor does not operate.
Wiring diagram:
Air conditioning system Ref. to WIRING SYSTEM (CROSSTREK MODEL (HEV))>AIR CONDITIONING SYSTEM>WIRING DIAGRAM .
- CHECK CONNECTOR
.
- Check connecting condition of the A/C control panel connector, heat pump control module connector and Exterior condenser outlet temperature sensor connector.
- Turn the ignition switch to ON.
- Read the DTC of [Air Conditioner] using the Subaru Select Monitor. Ref. to AIR CONDITIONER (DIAGNOSTICS) (HEV)>DIAGNOSTIC TROUBLE CODE (DTC) .
Is DTC B1456 displayed? (Current malfunction)
Yes: Go to 2.
No: Even if DTC is displayed, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.
NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause. - CHECK Exterior condenser outlet temperature sensor
.
- Turn the ignition switch to OFF.
- Disconnect Exterior condenser outlet temperature sensor. Ref. to AIR CONDITIONER (HEV)>PIPE TEMPERATURE SENSOR .
- Short the connector B658.
- Turn the ignition switch to ON.
- Read the DTC of [Air Conditioner] using the Subaru Select Monitor. Ref. to AIR CONDITIONER (DIAGNOSTICS) (HEV)>DIAGNOSTIC TROUBLE CODE (DTC) .
Is DTC B1457 displayed? (Current malfunction)
Yes: Replace Exterior condenser outlet temperature sensor. Ref. to AIR CONDITIONER (HEV)>PIPE TEMPERATURE SENSOR .
NOTE: If it is not possible to remove Exterior condenser outlet temperature sensor unit, replace it together with the condenser pipe Ref. to AIR CONDITIONER (HEV)>CONDENSER .No: Go to 3.
- CHECK HARNESS
.
- Turn the ignition switch to OFF.
- Restore the temporary shorted lines made in step 2.
- Turn the ignition switch to ON.
- Using a tester, measure the voltage between Exterior condenser outlet temperature sensor connector terminals.
Connector and terminal
(B658) No. 1 (+) - (B658) No. 2 (-):
Is the voltage 4.5 - 5.5 V?
Yes: Go to 4.
No: Repair or replace the open circuit of harness.
- CHECK HARNESS (OPEN CIRCUIT)
.
- Disconnect the heat pump control module connector.
- Using a tester, check the continuity between the heat pump control module connector and Exterior condenser outlet temperature sensor connector.
Connector and terminal
(B658) No. 1 - (i365) No. 8:
(B658) No. 2 - (i365) No. 30:
Is there continuity?
Yes: Replace the heat pump control module. Ref. to AIR CONDITIONER (HEV)>CONTROL UNIT .
No: Repair or replace the open circuit of harness.