Heat Pump Control Module
- Install the heat pump control module.
Tightening torque: 7.5 N.m (0.8 kgf-m, 5.5 ft-lb)
- Install the pocket assembly and the back panel - pocket. Ref. to EXTERIOR/INTERIOR TRIM>GLOVE BOX>INSTALLATION .
- Connect the battery ground terminal. Ref. to REPAIR CONTENTS>REPAIR CONTENTS>NOTE>BATTERY .
- When the heat pump control module was replaced with a new part, follow the procedure below to cancel the initialization prohibit state.
- Check that all connectors are locked securely.
- Turn the ignition switch to ON.
- Turn the fan dial to ON.
- Wait for 20 seconds or more, then turn the ignition switch to OFF.