Active Test: List
WARNING: This page is about a different variant/trim than selected.
NOTE:
If not equipped (depending on destination area or vehicle equipment condition), some items are not displayed.
| Active test item | Range | Contents | Execution condition | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| In-vehicle Air Temperature setting | -72.47 - 193.82°C | Set in-vehicle sensor readings. Adjusting the in-vehicle sensor value to use for A/C control is useful for reproduction test in faulty events. | Ignition switch ON
NOTE:
Engine ON is recommended.
|
||||||||
| Ambient Air Temperature Setting | -40 - 80°C | Set ambient sensor readings. Adjusting the ambient sensor value to use for A/C control is useful for reproduction test in faulty events. | Ignition switch ON
NOTE:
Engine ON is recommended.
|
||||||||
| Quantity of Sunload Setting | 0 - 4448 W/m2 | Set sunload sensor readings. Adjusting the sunload sensor value to use for A/C control is useful for reproduction test in faulty events. | Ignition switch ON
NOTE:
Engine ON is recommended.
|
||||||||
| Heater Water Temperature Setting | -40 - 214°C | Set coolant temperature sensor readings. Adjusting the coolant temperature sensor value to use for A/C control is useful for reproduction test in faulty events. | Engine ON | ||||||||
| AUTO switch mode setting | ON | Transmit ON signal of AUTO switch contact. By operating A/C with the signal, it is possible to judge whether the control is faulty or the switch (A/C control panel) is faulty. | Ignition switch ON
NOTE:
Engine ON is recommended.
|
||||||||
| Air mix door actuator target open (driver's side) | 0 - 100 % | Set the driver's seat air mix door actuator opening angle. Useful for reproduction test in faulty events. | Ignition switch ON
NOTE:
Engine ON is recommended.
|
||||||||
| Air mix door actuator target open (passenger's side) | 0 - 100 % | Set the passenger's seat air mix door actuator opening angle. Useful for reproduction test in faulty events. (1) |
Ignition switch ON
NOTE:
Engine ON is recommended.
|
||||||||
| Fresh/Rec Air Dr Act Target Open Angle | 0 - 100 % | Set the intake door actuator opening angle. Useful for reproduction test in faulty events. |
Ignition switch ON
NOTE:
Engine ON is recommended.
|
||||||||
| Mode Door Actuator Opening Angle Target | 0 - 100 % | Set the mode door actuator opening angle. Useful for reproduction test in faulty events. |
Ignition switch ON
NOTE:
Engine ON is recommended.
|
||||||||
| Blower Fan Level Setting | 0 - 100
NOTE:
Input up to 255 is possible, but 100 - 255 is the same.
|
Set the blower fan level. Useful for reproduction test in faulty events. | Ignition switch ON
NOTE:
|
||||||||
| A/C Change Setting | ON/OFF | Set the compressor operation request. Useful for reproduction test in faulty events.
NOTE:
Active test error may occur for the protection control of the engine or compressor.
|
|
||||||||
| Rear Defogger Setting | ON/OFF | Transmit the rear defogger switch contact signal. By operating A/C with the signal, it is possible to judge whether the control is faulty or the switch (A/C control panel) is faulty. | Ignition switch ON
NOTE:
Engine ON is recommended.
|
||||||||
| Variable Flow Change Solenoid Duty | 0 - 100 % | Set Duty value of variable flow change solenoid valve. Useful for reproduction test in faulty events. (2) |
|
||||||||
| Heater core temperature setting | -40 - 214°C | Set the heater core sensor readings. Adjusting the heater core sensor value to use for A/C control is useful for reproduction test in faulty events. (3) | Ignition switch ON
NOTE:
Engine ON is recommended.
|
||||||||
| Humidity Setting | 0 - 100 % | Set humidity sensor readings. Adjusting the humidity sensor value to use for A/C control is useful for reproduction test in faulty events. (4) | Ignition switch ON
NOTE:
Engine ON is recommended.
|
||||||||
|
|||||||||||