LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2021 >> Crosstrek Hybrid >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 25 (Engine Cooling System (Except For HEV)) >> Water Pipe >> Installation >> Water Pipe RH

Water Pipe RH

WARNING: This page is about a different variant/trim than selected.
  1. Set the water hose (front side) and the water pipe RH as an assembly.
  2. Install the bolts securing the water pipe RH.

    Tightening torque: 

    6.4 N.m (0.7 kgf-m, 4.7 ft-lb)

  3. Connect the water hose (rear side).
  4. Install the crossmember support - rear RH. Ref. to FRONT SUSPENSION>CROSSMEMBER SUPPORT> INSTALLATION .
  5. Install the front exhaust pipe. Ref. to EXHAUST (H4DO (EXCEPT FOR HEV))>FRONT EXHAUST PIPE>INSTALLATION .
  6. Connect the ground terminal to battery sensor. Ref. to REPAIR CONTENTS>REPAIR CONTENTS>NOTE>BATTERY .
  7. Fill engine coolant.

    2.0 L model:  Ref. to COOLING (H4DO (EXCEPT FOR HEV))>ENGINE COOLANT>REPLACEMENT>FILLING OF ENGINE COOLANT>2.0 L MODEL .

    2.5 L model:  Ref. to COOLING (H4DO (EXCEPT FOR HEV))>ENGINE COOLANT>REPLACEMENT>FILLING OF ENGINE COOLANT>2.5 L MODEL .