Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATIONS
| Malfunction Criteria | Threshold Value |
|---|---|
| Input pulse of the active grille shutter position sensor | Equal to 0 |
Time needed for diagnosis: 2000 ms
Malfunction indicator light illumination: Illuminates as soon as a malfunction occurs.