Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATIONS (MECHANICAL MALFUNCTION WARNING)
| Malfunction judgment criteria | Threshold Value |
|---|---|
| Internal malfunction flag of generator (mechanical malfunction warning) | ON |
| Generator revolution speed | More than 1550rpm |
JUDGMENT VALUE SPECIFICATIONS (ELECTRICAL MALFUNCTION WARNING)
| Malfunction judgment criteria | Threshold Value |
|---|---|
| Internal malfunction flag of generator (electrical malfunction warning) | ON |
Time needed for diagnosis:
Mechanical malfunction warning: 384 ms or more
Electrical malfunction warning: 2384 ms or more (in which, 2000 ms is delay time in the generator)
Malfunction indicator light illumination: Does not illuminate even when malfunction occurs. (Charge light illuminates)