2.5 L Model
WARNING: This page is about a different variant/trim than selected.
- Connect the vacuum hose to the purge control solenoid valve.
- Install the purge control solenoid valve bracket.
Tightening torque:
12 N.m (1.2 kgf-m, 8.9 ft-lb)
- Install the purge control solenoid valve.
Tightening torque:
6.4 N.m (0.7 kgf-m, 4.7 ft-lb)
- Connect the vacuum hose (C) to the intake manifold assembly, and install the vacuum hose (C) to the clip (D).
- Connect the evaporation hose (B), and connect the connector (A).
- Install the air intake boot. Ref. to INTAKE (INDUCTION) (H4DO (EXCEPT FOR HEV))>AIR INTAKE BOOT>INSTALLATION .
- Connect the ground terminal to battery sensor. Ref. to REPAIR CONTENTS>REPAIR CONTENTS>NOTE>BATTERY .