Execution Condition
WARNING: This page is about a different variant/trim than selected.
| Secondary parameters | Execution condition |
|---|---|
| Integrated time since compensation value status for each cylinder (refer to the Table) has turned to "In operation"* | 400time(s) (12.8 s) or more |
*: Time is calculated cumulatively. (If the secondary parameters are not satisfied for the compensation value status of each cylinder, the integrated time will not be reset.)
Table (status of each cylinder correction value)
| Secondary parameters | Execution condition |
|---|---|
| Main feedback | In operation |
| Engine speed | 1000rpm - 4000rpm |
| Engine load | 0.7g/rev (0.02 oz/rev) or more |
| Amount of intake air | 10g/s (0.35 oz/s) or more |
| Or, | |
| Main feedback | In operation |
| Engine speed | 1000rpm - 4000rpm |
| Engine load | 0.6g/rev (0.02 oz/rev) or more |
| Amount of intake air | 25g/s (0.88 oz/s) or more |