Diagnostic Method 2
WARNING: This page is about a different variant/trim than selected.
Detect the malfunction by calculating the average amplitude of λ.
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATIONS
| Malfunction Criteria | Threshold Value |
|---|---|
| Average value for λ amplitude | More than 0.075 |
Time needed for diagnosis: 90 s
Malfunction indicator light illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.