Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
Judge as NG when Low side or High side becomes NG.
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE SPECIFICATIONS (LOW)
| Malfunction Criteria | Threshold Value |
|---|---|
| Airflow amount | Less than 9.9g/s (0.35 oz/s) |
JUDGMENT VALUE SPECIFICATIONS (HIGH)
| Malfunction Criteria | Threshold Value |
|---|---|
| Airflow amount | 9.9g/s (0.35 oz/s) or more |
Time needed for diagnosis:
Low: 5000 ms
High: 5000 ms
Malfunction indicator light illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.