LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2021 >> Ascent Touring >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC System (Diagnostics) >> Diagnostic Procedure with Diagnostic Trouble Code (DTC) >> DTC B1446: Air Mix Door Actuator Circuit Stuck (Driver)

DTC B1446: Air Mix Door Actuator Circuit Stuck (Driver)

DTC detecting condition: 

Trouble symptom: 

Temperature on the driver's side cannot be adjusted.

Wiring diagram: 

Air conditioning system Ref. to WIRING SYSTEM>Air Conditioning System>WIRING DIAGRAM .

G13867014Courtesy of SUBARU OF AMERICA, INC.
CAUTION: Before performing diagnosis, refer to "CAUTION" in "General Description". Ref. to AIR CONDITIONER (DIAGNOSTICS)>General Description>CAUTION .
  1. CHECK CONNECTOR  .
    1. Check connecting condition of the A/C control module connector and air mix door actuator LH connector.
    2. Read the DTC of [Air Conditioner] using the Subaru Select Monitor. Ref. to AIR CONDITIONER (DIAGNOSTICS)>Diagnostic Trouble Code (DTC) .

    Is DTC B1446 displayed? (Current malfunction)

    Yes  : Go to  2.

    No:  Even if DTC is displayed, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.

    NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
  2. CHECK ACTUATOR  .

    Using the Subaru Select Monitor, check the following items in the [Active Test] of [Air Conditioner]. Ref. to AIR CONDITIONER (DIAGNOSTICS)>ACTIVE TEST .

    • [Air mix door actuator target open (driver's side)]

    Did the air mix door actuator LH move to the specified target opening angle?

    Yes:  Air mix door actuator LH circuit is normal.

    No:  Go to  3.

  3. CHECK HARNESS  .
    1. Turn the ignition switch to ON.
    2. Using a tester, measure the voltage between air mix door actuator LH connector terminals.

      Connector & terminal 

      (i174) No. 3 (+) - (i174) No. 1 (-):

    Is the voltage 4.5 - 5.5 V?

    Yes  : Go to  4.

    No:  Repair or replace the open, short circuit of the harness.

  4. CHECK HARNESS (OPEN CIRCUIT)  .
    1. Disconnect the connector from A/C control module.
    2. Using a tester, check the continuity between A/C control module connector and air mix door actuator connector LH terminals.

      Connector & terminal 

      (i174) No. 3 - (i329) No. 12:

      (i174) No. 1 - (i329) No. 24:

      (i174) No. 2 - (i329) No. 11:

      (i174) No. 5 - (i329) No. 7:

      (i174) No. 4 - (i329) No. 8:

    Is there continuity?

    Yes  : Go to  5.

    No:  Repair or replace the open circuit of harness.

  5. CHECK AIR MIX DOOR ACTUATOR LH  .

    Check the air mix door actuator LH parts. Ref. to AIR CONDITIONER>AIR MIX DOOR ACTUATOR .

    Is the air mix door actuator LH normal?

    Yes:  Replace the A/C control module. Ref. to AIR CONDITIONER>CONTROL UNIT .

    No:  Replace the air mix door actuator LH. Ref. to AIR CONDITIONER>AIR MIX DOOR ACTUATOR .