52 Ω Or Less
- MAIN-CAN
Wiring diagram:
CAN communication system Ref. to WIRING SYSTEM>CAN Communication System>WIRING DIAGRAM .
- CHECK BETWEEN RELATED LINES AND MAIN WIRING HARNESS .
- CHECK MAIN WIRING HARNESS AND RELATED LINES
.
With a tester connected, disconnect control module connectors in order.
NOTE: Disconnect the body integrated unit at the end.Connector & terminal
(i74) No. 2 - (i74) No. 3:
Is there any control module whose condition has changed from short state?
Yes : Replace the control module whose resistance has changed. When the value changed at disconnecting the body integrated unit, replace the body integrated unit. Ref. to SECURITY AND LOCKS>Body Integrated Unit>REMOVAL .
Go to 3.
No : Repair or replace the short circuit of the harness between body integrated unit and ECM.
- CHECK CONTROL MODULE
.
- Disconnect the connectors of ECM and body integrated unit.
- Using a tester, measure the resistance between control module terminals.
Connector & terminal
(B134) No. 45 - (B134) No. 58:
(i171) No. 1 - (i171) No. 2:
Is the resistance 114 - 126 Ω?
Yes : Go to 4.
No : Replace the control module whose end resistance value is out of the specified range.
- CHECK HARNESS
.
Measure the resistance between body integrated unit connector terminals using tester.
Connector & terminal
(i171) No. 1 - (i171) No. 2:
Is the resistance 1 MΩ or more?
Yes : CAN communication circuit is normal.
No : Go to 5.
- CHECK CONTROL MODULE
.
With a tester connected, disconnect control modules in order.
Connector & terminal
(i171) No. 1 - (i171) No. 2:
Are there any control modules whose resistance changed to 1 MΩ or more?
Yes : Replace the control module that has changed.
No : Repair or replace the harness part which has resistance component.
- BODY-CAN
Wiring diagram:
CAN communication system Ref. to WIRING SYSTEM>CAN Communication System>WIRING DIAGRAM .
- CHECK BETWEEN RELATED LINES AND MAIN WIRING HARNESS .
- CHECK MAIN WIRING HARNESS AND RELATED LINES
.
With a tester connected, disconnect control module connectors in order.
NOTE: Disconnect the body integrated unit at the end.Connector & terminal
(i87) No. 9 - (i87) No. 10:
Is there any control module whose condition has changed from short state?
Yes : Replace the control module whose resistance has changed. When the value changed at disconnecting the body integrated unit, replace the body integrated unit. Ref. to SECURITY AND LOCKS>Body Integrated Unit>REMOVAL .
Go to 3.
No : Repair or replace the short circuit of the harness between body integrated unit and combination meter.
- CHECK CONTROL MODULE
.
- Disconnect the connectors of the body integrated unit and combination meter.
- Using a tester, measure the resistance between control module terminals.
Connector & terminal
(B281) No. 17 - (B281) No. 19:
(i10) No. 6 - (i10) No. 7:
Is the resistance 114 - 126 Ω?
Yes : Go to 4.
No : Replace the control module whose end resistance value is out of the specified range.
- CHECK HARNESS
.
Using a tester, measure the resistance between the combination meter connector terminals.
Connector & terminal
(i10) No. 6 - (i10) No. 7:
Is the resistance 1 MΩ or more?
Yes : CAN communication circuit is normal.
No : Go to 5.
- CHECK CONTROL MODULE
.
With a tester connected, disconnect control modules in order.
Connector & terminal
(i10) No. 6 - (i10) No. 7:
Are there any control modules whose resistance changed to 1 MΩ or more?
Yes : Replace the control module that has changed.
No : Repair or replace the harness part which has resistance component.