Related Lines, More Than 52 Ω And Less Than 62 Ω (Body Can_Seat Ventilation)
Wiring diagram:
CAN communication system Refer to WIRING SYSTEM>CAN Communication System>WIRING DIAGRAM .
- CHECK BETWEEN RELATED LINES AND MAIN WIRING HARNESS
.
- Disconnect the seat ventilation Control Module connector.
- Using a tester, measure the resistance between the seat ventilation Control Module connector terminals.
Connector & terminal
(St41) No. 9 - (St41) No. 10:
Is the resistance 400 Ω or more?
Yes: A related line between seat ventilation Control Module and main wiring harness is open, or main wiring harness is open at two places or more.
No: Go to 2.
- CHECK RELATED LINES
.
Using a tester, measure the resistance between seat ventilation Control Module connector and central gateway Control Module connector.
Connector & terminal
(St41) No. 9 - (i88) No. 6:
(St41) No. 10 - (i88) No. 5:
Is the resistance 10 Ω or more?
Yes: Repair or replace the open circuit of seat ventilation related lines.
No: CHECK DTC of ventilation seat system. Refer to VENTILATION SEAT (DIAGNOSTICS)>DIAGNOSTIC TROUBLE CODE (DTC) .