Inspection Without Using Can Diagnostic
Trouble causes:
- Electrical system malfunction
- Faulty harness and harness connector
CAUTION:
Before performing diagnosis, refer to "CAUTION" in "General Description". Refer to LAN SYSTEM (DIAGNOSTICS)>General Description>CAUTION .
- CHECK BATTERY
.
Check the battery. Refer to STARTING/CHARGING SYSTEMS (H4DO)>Battery . Refer to STARTING/CHARGING SYSTEMS (H4DOTC)>Battery .
Is the check result OK?
Yes: Go to 2.
No: Charge or replace the battery.
- CHECK FUSE
.
Check the fuse which might affect the problem.
Is the check result OK?
Yes: Go to 3.
No: Replace the fuse. If the replaced fuse blows out easily, some type of fault is present. Therefore, repair the faulty portion.
- CHECK HARNESS
.
Check the harness and harness connector connection which might affect the problem.
Is the check result OK?
Yes: Go to step 3 in the Basic Diagnostic Procedure. Refer to LAN SYSTEM (DIAGNOSTICS)>Basic Diagnostic Procedure>PROCEDURE .
No: Repair or replace the faulty harness or harness connector.