Execution Condition
WARNING: This page is about a different variant/trim than selected.
| Secondary parameters | Execution condition |
|---|---|
| Phase 1 | |
| 12 V battery system voltage | 10 V or more |
| Engine speed | At or more than rpm values in Table 1 |
| Phase 2 | |
| Fail detected (P1867) | TRUE |
| 12 V battery system voltage | 10 V or more |
| Ignition state | OFF |
| Measured primary pulley shaft speed | 400 rpm or less |
| Transmission fluid temperature | 5 degC or more |
TARGET LINE PRESSURE SPECIFICATION
| Target line pressure (kPa) | ||||||||||
| 0 | 500 | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6000 | ||
| Transmission fluid temperature (degC) | -40 | 500 | 500 | 500 | 500 | 500 | 500 | 574 | 8000 | 8000 |
| -20 | 500 | 500 | 500 | 500 | 500 | 500 | 574 | 8000 | 8000 | |
| 0 | 500 | 500 | 500 | 500 | 500 | 500 | 574 | 8000 | 8000 | |
| 20 | 500 | 500 | 500 | 500 | 500 | 500 | 574 | 8000 | 8000 | |
| 40 | 500 | 500 | 500 | 526 | 558 | 626 | 745 | 8000 | 8000 | |
| 60 | 500 | 515 | 554 | 592 | 629 | 703 | 816 | 8000 | 8000 | |
| 80 | 516 | 611 | 658 | 705 | 751 | 841 | 1273 | 8000 | 8000 | |
| 100 | 598 | 694 | 751 | 806 | 861 | 967 | 1966 | 8000 | 8000 | |
| 120 | 684 | 789 | 858 | 921 | 980 | 1245 | 3553 | 8000 | 8000 | |