Related Lines, More Than 56 Ω And Less Than 64 Ω (C-Can_Stereo Camera)
WARNING: This page is about a different variant/trim than selected.
Wiring diagram:
CAN communication system Ref. to WIRING SYSTEM (CROSSTREK MODEL (HEV))>CAN COMMUNICATION SYSTEM>WIRING DIAGRAM .
NOTE:
When the measured resistance value is more than 56 Ω and less than 64 Ω, main wiring harness or related lines may be shorted to ground, or shorted to power supply line, or related lines may be open.
- CHECK BETWEEN RELATED LINES AND MAIN WIRING HARNESS
.
- Disconnect the stereo camera connector.
- Using a tester, measure the resistance between terminals in stereo camera connector.
Connector & terminal
(R137) No. 9 - (R137) No. 10:
Is the resistance 400 Ω or more?
Yes : A related line between stereo camera and main wiring harness is open, or main wiring harness is open at two places or more.
No : Go to 2.
- CHECK RELATED LINES
.
- Disconnect the central gateway Control Module connector.
- Using a tester, measure the resistance between the stereo camera connector and central gateway Control Module connector.
Connector & terminal
(R137) No. 10 - (i366) No. 23:
(R137) No. 9 - (i366) No. 8:
Is the resistance 10 Ω or more?
Yes : Repair or replace the open circuit of stereo camera related lines.
Yes : Check DTC of stereo camera. Ref. to EYESIGHT (DIAGNOSTICS) (HEV)>DIAGNOSTIC TROUBLE CODE (DTC) .