Related Lines, More Than 52 Ω And Less Than 62 Ω (Body-Can_Keyless Access System)
Wiring diagram:
CAN communication system Ref. to WIRING SYSTEM (CROSSTREK MODEL (HEV))>CAN COMMUNICATION SYSTEM>WIRING DIAGRAM .
- CHECK BETWEEN RELATED LINES AND MAIN WIRING HARNESS
.
- Disconnect the keyless access Control Module connector.
- Using the tester, measure the resistance between terminals.
Connector & terminal
(i241) No. 30 - (i241) No. 29:
Is the resistance 400 Ω or more?
Yes : A related line between keyless access Control Module and main wiring harness is open, or main wiring harness is open at two places or more.
No : Go to 2.
- CHECK RELATED LINES
.
Using a tester, measure the resistance between the keyless access Control Module connector and audio or navigation unit connector.
Connector & terminal
(i241) No. 30 - (i87) No. 9:
(i241) No. 29 - (i87) No. 10:
Is the resistance 10 Ω or more?
Yes : Repair or replace the open circuit of keyless access Control Module related lines.
No : Check DTC of keyless access Control Module. Ref. to KEYLESS ACCESS WITH PUSH BUTTON START (DIAGNOSTICS)>DIAGNOSTIC TROUBLE CODE (DTC) .