LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2020 >> Crosstrek Base, Automatic CVT Trans >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC System (Heater, Ventilator And A/C) (Except For HEV) >> Refrigerant Pressure With Manifold Gauge Set >> Inspection >> High-Pressure Side Is High

High-Pressure Side Is High

  1. CHECK CONDENSER  .

    Check the condenser. Refer to AIR CONDITIONER (EXCEPT FOR HEV)>CONDENSER>INSPECTION .

    Is condenser OK?

    Yes  : Go to  2.

    No  : Clean or replace the condenser.

  2. CHECK RADIATOR FAN  .

    Check the radiator fan system. Refer to COOLING (H4DO (EXCEPT FOR HEV))>RADIATOR FAN SYSTEM .

    Is radiator fan system normal?

    Yes  : Go to  3.

    No  : Repair the radiator fan system or replace the faulty parts.

  3. FILL PROPER AMOUNT OF REFRIGERANT  .

    Drain all refrigerant, and refill proper amount of refrigerant.

    Is refrigerant pressure within the standard value?

    Yes  : Refrigerant pressure is normal.

    No  : Check the high-pressure hose and condenser for kinks or clogging, and replace if defective.