  1. Check the motor operation when battery voltage is applied between the connector terminals.
    G13235645Courtesy of SUBARU OF AMERICA, INC.
    Terminal No. Inspection conditions Specification
    2 (+) - 3 (-) Apply battery voltage. Rotation
  2. If it does not operate normally, replace the charger cooling blower.