On-Vehicle Inspection For Electric Vehicle Charger Cable Assembly

WARNING: This page is about a different variant/trim than selected.
NOTE:
  • Use an Electric vehicle charger cable assembly and AC power supply which were confirmed to operate normally, and judge whether or not the Electric vehicle charger cable assembly is normal.
  • When an abnormality is detected, the CCID relay immediately shuts off and the supply of power to the vehicle is stopped.
  • When checking charging, use Subaru Select Monitor and check that [Hybrid Battery SOC] from the list of Data Monitor items is less than 70%. Refer to P-HEV HIGH VOLTAGE BATTERY (DIAGNOSTICS)>DATA MONITOR .
  • If the [Hybrid Battery SOC] is 70% or more, the Electric vehicle charger cable assembly charging indicator may not illuminate even if the Electric vehicle charger cable assembly (charging connector) is inserted into the inlet AC charger cable (charging inlet) and charging is started.
  • If the Electric vehicle charger cable assembly (charging inlet) is shaken during plug-in charging then charging may stop in order to ensure safety.
  • The Electric vehicle charger cable assembly does not affect the EV traveling distance display.
  1. Check regular charging.

    Connect the Electric vehicle charger cable assembly and perform regular charging.

    CAUTION:
    • Use an AC power supply which was confirmed to operate normally.
    • Use an Electric vehicle charger cable assembly which was confirmed to operate normally.
  2. If the trouble is not reproduced, (*A)

    Connect the Electric vehicle charger cable assembly and perform regular charging.

    CAUTION:
    • Use an AC power supply which was confirmed to operate normally.
    • Use the Electric vehicle charger cable assembly that you want to check.
  3. If the trouble is reproduced, (*B)

    During plug-in charging, check the status of the Electric vehicle charger cable assembly power indicator, charging indicator, and error indicator under the conditions shown in the table below.

    G13607562Courtesy of SUBARU OF AMERICA, INC.
    Power indicator status Charging indicator status Error indicator status Contents Detecting condition Outlet connection Charging inlet connection Action to take
    Light ON - Light OFF Voltage at the power plug - - -
    Light OFF - Light OFF No voltage at the power plug - x -
    1. Connect the power plug to the outlet.
    2. Check whether or not there is voltage at the outlet.
    1. Malfunction of CCID internal power supply
    2. Malfunction of CCID power supply indicator
    1. CCID internal power supply does not start.
    2. Open circuit in power supply indicator circuit
    - Replace the Electric vehicle charger cable assembly.
    Light ON Light OFF Blinking (1 time) CCID relay welding error There is relay output when CCID relay is not ON. - Replace the Electric vehicle charger cable assembly.
    Light ON Light OFF Blinking (2 times) CCID relay welding stuck error There is no relay output when CCID relay is ON. Replace the Electric vehicle charger cable assembly.
    Light ON Light OFF Blinking (3 times) Electrical leakage error Leakage detection function activated.
    1. Electrical leakage at vehicle
    2. Electrical leakage inside Electric vehicle charger cable assembly
    - Replace the Electric vehicle charger cable assembly.
    Light ON Light OFF Blinking (4 times) CPLT (duty) error Area where duty of less than 5% or 40% or more is detected. Replace the Electric vehicle charger cable assembly.
    Light ON Light OFF Blinking (5 times) CPLT (-12V) error -12V is not detected when duty is ON.
    1. Electric vehicle charger assembly electronic component malfunction
    2. Electric vehicle charger cable assembly internal malfunction
    Replace the Electric vehicle charger cable assembly.
    Light ON Light OFF Blinking (6 times) Electrical leakage self-diagnosis error Electrical leakage self-diagnosis system does not operate correctly. Replace the Electric vehicle charger cable assembly.
    Blink (0.25 sec intervals) - Light OFF Power plug abnormal heating detection Abnormal heating of the power plug was detected.
    1. Heating of outlet connection
    2. Malfunction inside power plug
    - Check the connection at multiple outlets.
    1. If the problem is reproduced at a particular outlet, check the outlet connection.
    2. If the problem is reproduced at multiple outlets: Replace the EV charger plug assembly.
    Blink (0.25 sec intervals) - Blink (0.25 sec intervals) Power supply plug temperature detector malfunction There is a malfunction of the power plug temperature detector. - Check for open circuit in EV charger plug assembly.
    Light ON - Blink (0.25 sec intervals) Energizing function stop warning The charging count has reached the specified number. - -
    Light ON - Light ON Energizing function stop The total number of charges has reached the specified number. - Replace the Electric vehicle charger cable assembly.
    • ◦: Normal
    • x: Malfunction
    NOTE:
    • If there is electrical leakage (example shows blinking 3 times):

      Blinking of the power indicator occurs at the timing shown in the figure below.

      G13607563Courtesy of SUBARU OF AMERICA, INC.
    • If there is a power supply plug temperature detector malfunction (example shows blinking at 0.25 sec intervals):

      Blinking of the power indicator and error indicator occurs at the timing shown in the figure below.

      G13607564Courtesy of SUBARU OF AMERICA, INC.
    • When the charging count reaches the specified number, the CCID energizing function is stopped.