Item Contents Standard/Unit Note
In-vehicle Sensor Temperature Display the in-vehicle sensor value. -72.47 - 193.82°C -
Refrigerant Pressure Display the pressure sensor value. 0 - 3.29 Mpa -
Quantity of Sunload Display the sunload sensor value. 0 - 4448 W/m2 -
Heater Water Temperature Display the engine coolant temperature. (CAN information) -40.00 - 214 °C -
Heater Control Panel Setting Value (Driver's) Display the set temperature of the A/C control panel on driver's seat side. 15 - 90 -
Blower outlet request temperature (Driver's) Display the inner set value of the A/C control panel. -327.68 - 327.67°C -
Air mix door actuator position (driver's side) Display the driver's seat air mix door actuator position information. -32.68 - 133.33 % -
Mode Door Actuator Position Display the mode door actuator position information. -32.68 - 133.33 % -
Fresh/Recircle Air Door Actuator Position Display the intake door actuator position information. -32.68 - 133.33 % -
Target air mix door actuator position (driver's side) Display the driver's seat air mix door actuator target position information. -32.68 - 133.33 % -
Mode Door Actuator Position Target Display the mode door actuator target position information. -32.68 - 133.33 % -
Fresh/Recircle Air Door Actuator Position Target Display the intake door actuator target position information. -32.68 - 133.33 % -
Blower Fan Level Display the blower fan motor speed level. 0 - 255 -
Ambient Air Temperature Display the ambient sensor value. (CAN information) -40 - 80 °C -
Compressor operation status Display the operation status of the compressor. OFF/ON -
Blower Fan Operating Condition Display the operation status of the blower fan. MANU/AUTO -
A/C Operating Condition Display the operation status of the compressor. MANU/AUTO -
Fresh/Recircle Air Operating Condition Display the operation status of the FRESH/RECIRC. MANU/AUTO -
Mode Operating Condition Display the operation status of the blow vents. MANU/AUTO -
Rear Defogger Display the operation status of the rear defogger switch. OFF/ON -
Engine Speed Display the engine speed. (CAN information) 0 - 32767 rpm -
Vehicle Speed Display the vehicle speed. (CAN information) 0 - 300 km/h -
Evaporator Temperature Display the evaporator sensor value. -82.48 - 153.55°C -
Evaporator Temperature Target Display the evaporator target temperature. 0 - 20 °C -
Discharge Refrigerant Temperature Discharged refrigerant temperature is displayed. -40 - 214 °C -
Inner Condenser Out Refrigerant Temperature Interior condenser outlet refrigerant temperature is displayed. -40 - 214 °C -
External Condenser Out Refrigerant Temperature Exterior condenser outlet refrigerant temperature is displayed. -40 - 214 °C -
Evaporator Out Refrigerant Temperature Evaporator outlet refrigerant temperature is displayed. -40 - 214 °C -
High Pressure Solenoid Valve Drive State Drive status of High pressure solenoid valve is displayed. OFF/ON -
Low Pressure Solenoid Valve Drive State Drive status of Low pressure solenoid valve is displayed. OFF/ON -
Cooling Expansion Valve Drive State Drive status of Cooling expansion valve is displayed. 0 - 100% -
Heating Expansion Valve Driving State Drive status of Heating expansion valve is displayed. 0 - 100% -
Target Air Temperature Behind Inner Condenser Target air temperature after the interior condenser is displayed. -40 - 214 °C -
Estimated Air Temperature Behind Inner Condenser Estimated air temperature after the interior condenser is display. -40 - 214 °C -
Operation Cycle State Drive cycle status is displayed. 01: Cooling
02: Dehumid.(S)
03: Dehumid. (P)
04: Heating
05: Defrosting
06: Idol
07: Initialize
-
Electric driven compressor target speed Electric compressor ASSEMBLY target speed is displayed. 0 - 32767 rpm -
Blower outlet Door Request Temperature Display the blow vents target temperature. -327.68 - 327.67°C -
PTC operation steps Display the blow vents target temperature. 0 - 3 -
PTC Heater 1 Display operation status of PTC 1st level. Inoperative/Operate -
PTC Heater 2 Display operation status of PTC 2nd level. Inoperative/Operate -
PTC Heater 3 Display operation status of PTC 3rd level. Inoperative/Operate -
Request engine speed Display the request engine speed. 0: Without Request
  1. Cooler H
  2. Heater H
  3. Cooler L
  4. Heater L
  5. Heater M
  6. Heater LL
-
Heater core Temp. Heater core sensor reading is displayed. -40 - 214 °C -