Active Test: List
WARNING: This page is about a different variant/trim than selected.
NOTE:
If not equipped (depending on destination area or vehicle equipment condition), some items are not displayed.
| Active test items | Range | Contents | Execution condition |
|---|---|---|---|
| In-vehicle Air Temperature setting | -72.47 - 193.82°C | Set in-vehicle sensor readings. Adjusting the in-vehicle sensor value to use for A/C control is useful for reproduction test in faulty events. | Ignition switch ON
NOTE:
READY ON is recommended.
|
| Ambient Air Temperature Setting | -40 - 80 °C | Set ambient sensor readings. Adjusting the ambient sensor value to use for A/C control is useful for reproduction test in faulty events. | Ignition switch ON
NOTE:
READY ON is recommended.
|
| Quantity of Sunload Setting | 0 - 4448 W/m2 | Set sunload sensor readings. Adjusting the sunload sensor value to use for A/C control is useful for reproduction test in faulty events. | Ignition switch ON
NOTE:
READY ON is recommended.
|
| Heater Water Temperature Setting | -40 - 214 °C | Set coolant temperature sensor readings. Adjusting the coolant temperature sensor value to use for A/C control is useful for reproduction test in faulty events. | READY ON |
| AUTO switch mode setting | ON | Transmit ON signal of AUTO switch contact. By operating A/C with the signal, it is possible to judge whether the control is faulty or the switch (A/C control panel) is faulty. | Ignition switch ON
NOTE:
READY ON is recommended.
|
| Air mix door actuator target open (driver's side) | 0 - 100% | Set the driver's seat air mix door actuator opening angle. Useful for reproduction test in faulty events. | Ignition switch ON
NOTE:
READY ON is recommended.
|
| Fresh/Rec Air Dr Act Trgt Open Angle | 0 - 100% | Set the intake door actuator opening angle. Useful for reproduction test in faulty events. | Ignition switch ON
NOTE:
READY ON is recommended.
|
| Mode Door Actuator Opening Angle Target | 0 - 100% | Set the mode door actuator opening angle. Useful for reproduction test in faulty events. | Ignition switch ON
NOTE:
READY ON is recommended.
|
| Blower Fan Level Setting | 0 - 100
NOTE:
Input up to 255 is possible, but 100 - 255 is the same.
|
Set the blower fan level. Useful for reproduction test in faulty events. | Ignition switch ON
NOTE:
|
| A/C Change Setting | ON/OFF | Set the compressor operation request. Useful for reproduction test in faulty events.
NOTE:
Active test error may occur for the protection control of the engine or compressor.
|
|
| Rear Defogger Setting | ON/OFF | Transmit the rear defogger switch contact signal. By operating A/C with the signal, it is possible to judge whether the control is faulty or the switch (A/C control panel) is faulty. | Ignition switch ON
NOTE:
READY ON is recommended.
|
| PTC steps | 0 - 3 | Set PTC level. Useful for reproduction test in faulty events. |
NOTE:
The setting value may not be obtained due to power supply circuit protection.
|
| Heater core temperature setting | -40 - 214 °C | Set the heater core sensor readings. Adjusting the heater core sensor value to use for A/C control is useful for reproduction test in faulty events. | Ignition switch ON
NOTE:
READY ON is recommended.
|
| High pressure electromagnetic valve | ON/OFF | High pressure solenoid valve is set. Useful for reproduction check in faulty events. | Ignition switch ON
NOTE:
READY ON is recommended.
|
| Low pressure electromagnetic valve | ON/OFF | Low pressure solenoid valve is set. Useful for reproduction check in faulty events. | Ignition switch ON
NOTE:
READY ON is recommended.
|
| Electric expansion valve for heating | 5 - 100%
NOTE:
Input 0% up to 100% is possible, but use the range of 5 to 100%.
|
Electric expansion valve for heating is set. Useful for reproduction check in faulty events. |
|
| Electric expansion valve for cooling | 20 - 38%
NOTE:
Input 0% up to 100% is possible, but use the range of 20 to 38%.
|
Electric expansion valve for cooling is set. Useful for reproduction check in faulty events. |
|
| Electric compressor target revolution speed | 1000 - 8600 rpm
NOTE:
|
Electric compressor target revolution speed is set. Useful for reproduction check in faulty events. |
|