Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Max. value - min. value of fuel level | Less than 2.6L (0.69US gal, 0.57Imp gal) |
Time needed for diagnosis: Less than 1 s
Malfunction indicator light illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.