Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value | ||
|---|---|---|---|
| Evaporative Leak Check Module pressure | More than -400Pa (-3 mmHg, -0.1 inHg) | ||
| Purge gas amount integrated value | 3g (0.11 oz) or more(1) | ||
|
|||
Time needed for diagnosis: Less than 1 s
Malfunction indicator light illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.