LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2020 >> Crosstrek Base, Automatic CVT Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 22 (Engine Control System (Diagnostics) (HEV) (4 Of 4)) >> Diagnostic Procedure with Diagnostic Trouble Code (DTC) >> DTC P24B9: EVAP System Leak Detection Pump Pressure Sensor Circuit Range/Performance >> General Description >> Execution Condition

Execution Condition

WARNING: This page is about a different variant/trim than selected.
DIAGNOSIS 1 - EXECUTION CONDITION

Secondary parameters Execution condition
Elapsed time after ignition switch is turned to ON
Soaking time
Vacuum pump in the leak check valve assembly
Switching valve in the leak check valve assembly
Purge control
500 ms or more
and
Less than 60000 ms
60s or more
Not in operation
Open
Not in operation
DIAGNOSIS 2 - EXECUTION CONDITION

Secondary parameters Execution condition
Elapsed time after Auto Start Stop control
Purge control
5000 ms or more
Not in operation