When "12V Battery Inspection Required" Is Displayed On The Meter
WARNING: This page is about a different variant/trim than selected.
- CHARGE BATTERY
.
Charge the battery. Ref. to STARTING/CHARGING SYSTEMS (H4DO (HEV))>BATTERY>CHARGE .
Is the battery charged?
Yes : Go to 2.
No
- Replace the battery with a new part. Ref. to STARTING/CHARGING SYSTEMS (H4DO (HEV))>BATTERY .
- Go to 3.
- CHECK BATTERY
.
Check the battery. Ref. to STARTING/CHARGING SYSTEMS (H4DO (HEV))>BATTERY>INSPECTION .
Is the battery OK?
Yes : Go to 3.
No
- Replace the battery with a new part. Ref. to STARTING/CHARGING SYSTEMS (H4DO (HEV))>BATTERY .
- Go to 3.
- CHECK WIRING AND TERMINAL (BETWEEN BATTERY (12V) - HYBRID VEHICLE CONTROL ECU ASSEMBLY)
.
Check the wiring and terminals.
Are the wiring and the contact of the terminal normal?
Yes : System is normal.
Restore the vehicle and repeat IG OFF (for three seconds) ↔ IG ON (for three seconds) three times or more with all the electric load turned OFF. Then confirm that "12V battery inspection required" is not displayed on the meter.
No
- Repair the defective part.