DTC P0D38-28: Hybrid/EV Battery Charger Input Current Sensor Circuit Signal Bias Level Out Of Range/Zero Adjustment Failure: Notes
WARNING: This page is about a different variant/trim than selected.
Outline of diagnosis:
IAC current flowed when the charger was stopped.
(1 trip detection logic)
Trouble symptom:
Plug-in charging suspended
NOTE:
This DTC is output when the Electric vehicle charger assembly detects an abnormality in the internal operation conditions.
Therefore if this DTC was detected, replace the Electric vehicle charger assembly. Ref. to HYBRID ELECTRIC VEHICLE>ELECTRIC VEHICLE CHARGER .
Therefore if this DTC was detected, replace the Electric vehicle charger assembly. Ref. to HYBRID ELECTRIC VEHICLE>ELECTRIC VEHICLE CHARGER .