Freeze Frame Data: List
WARNING: This page is about a different variant/trim than selected.
| Item | Contents | Display range | Note |
|---|---|---|---|
| Calculate Load | Calculate load (value increases in proportion to increase in load) | Min.: 0.0%, Max.: 100.0% | - |
| Coolant Temperature | Engine coolant temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | Cold or warmed-up engine |
| Engine Speed | Engine speed | Min.: 0 rpm, Max.: 16383 rpm | - |
| Vehicle Speed | Vehicle speed | Min.: 0 km/h (0 MPH), Max.: 255 km/h (158 MPH) | Stopped, or driving (at low, medium, or high speeds) |
| Intake Air Temperature | Intake air temperature | Min.: -40°C (-40°F), Max.: 140°C (284°F) | - |
| Throttle Position Sensor No. 1 Voltage % | Throttle position sensor | Min.: 0.0%, Max.: 100.0% | - |
| Engine Run Time | Elapsed time after starting engine | Min.: 0 sec, Max.: 65535 sec | After the power switch is turned on (READY), elapsed time from initial engine start until the power switch is turned off. |
| MIL ON Run Distance | Drive distance from MIL on | Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) | - |
| Warmup Cycle Cleared DTC | Warmup cycles after DTCs cleared | Min.: 0, Max.: 255 | - |
| Distance from DTC Cleared | Distance driven after DTCs cleared | Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) | - |
| Battery Voltage | Battery (12V) voltage | Min.: 0.00 V, Max.: 16.00 V | Battery (12V) and DC/DC converter condition |
| Ambient Temperature | Ambient air temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - |
| Running Time from MIL ON | Running time from MIL on | Min.: 0 min, Max.: 65535 min | - |
| Time after DTC Cleared | Time after DTCs cleared | Min.: 0 min, Max.: 65535 min | - |
| Shift SW Status (N, P Range) | Shift lever position sensor | ON or OFF | - |
| Hybrid/EV Battery System Voltage | HV battery voltage | Min.: 0.00 V, Max.: 1023.98 V | - |
| Hybrid/EV Battery System Current | HV battery current | Min.: -3276.8 A, Max.: 3276.7 A | HV battery charge/discharge status
|
| Boosting Converter Temperature (Upper) | Boost converter temperature (Upper) | Min.: 8°C (46.4°F), Max.: 150°C (302°F) | - |
| Boosting Converter Temperature 1 (Lower) | Boost converter temperature 1 (Lower) | Min.: 8°C (46.4°F), Max.: 150°C (302°F) | - |
| Boosting Converter Temperature 2 (Lower) | Boost converter temperature 2 (Lower) | Min.: 8°C (46.4°F), Max.: 150°C (302°F) | - |
| Motor Inverter Temperature | Motor inverter temperature | Min.: 8°C (46.4°F), Max.: 150°C (302°F) | - |
| Motor U Current (Lower Resolution) | Motor U current (Lower resolution) | Min.: -3276.8 A, Max.: - 3276.7 A | - |
| Motor V Current (Lower Resolution) | Motor V current (Lower resolution) | Min.: -3276.8 A, Max.: 3276.7 A | - |
| Motor W Current (Lower Resolution) | Motor W current (Lower resolution) | Min.: -3276.8 A, Max.: 3276.7 A | - |
| Generator U Current (Lower Resolution) | Generator U current (Lower resolution) | Min.: -3276.8 A, Max.: 3276.7 A | - |
| Generator V Current (Lower Resolution) | Generator V current (Lower resolution) | Min.: -3276.8 A, Max.: 3276.7 A | - |
| Generator W Current (Lower Resolution) | Generator W current (Lower resolution) | Min.: -3276.8 A, Max.: 3276.7 A | - |
| Motor ECM Power Supply (For 31V) | Motor generator control ECU power supply (for 31V) | Min.: 0.00 V, Max.: 4.98 V | - |
| Motor ECM Power Supply (For AD0) | Motor generator control ECU power supply (for AD0) | Min.: 0.00 V, Max.: 4.98 V | - |
| Motor ECM Power Supply (For 2.5 V) | Motor generator control ECU power supply (for 2.5 V) | Min.: 0.00 V, Max.: 4.98 V | - |
| Motor ECM Power Supply (For 2.5 V Sub) | Motor generator control ECU power supply (for 2.5 V sub) | Min.: 0.00 V, Max.: 4.98 V | - |
| DC/DC Converter Operation State | DC/DC converter operation state | Min.: 0.00 V, Max.: 4.98 V | - |
| DC/DC Converter Output Signal | DC/DC converter output signal | Min.: 0.00 V, Max.: 4.98 V | - |
| DC/DC Converter Output Signal Duty | DC/DC converter output duty | Min.: 0.0%, Max.: signal 100.0% | - |
| Motor Revolution | Motor speed (detected by resolver sensor) | Min.: -32768 rpm, Max.: 32767 rpm | Motor speed
|
| Motor Torque | Motor torque value | Min.: -4096.000 Nm, Max.: 4095.875 Nm | |
| Motor Control Mode | Motor control mode | Min.: 0, Max.: 65535 | - |
| Motor Carrier Frequency | Motor carrier frequency | 0.75 kHz/1.25 kHz/2.5 kHz/3.75 kHz/5 kHz/10 kHz | - |
| Motor Inverter Shut Down Signal | Motor inverter shutdown signal | Min.: 0, Max.: 255 | - |
| Generator Revolution | Generator speed (detected by resolver sensor) | Min.: -32768 rpm, Max.: 32767 rpm | Generator speed
|
| Generator Torque | Generator torque value | Min.: -4096.000 Nm, Max.: 4095.875 Nm | |
| Generator Control Mode | Generator control mode | Min.: 0, Max.: 65535 | - |
| Generator Carrier Frequency | Generator carrier frequency | 0.75 kHz/1.25 kHz/2.5 kHz/3.75 kHz/5 kHz/10 kHz | - |
| Generator Inverter Shut Down Signal | Generator inverter shutdown signal | Min.: 0, Max.: 255 | - |
| Inverter Coolant Temperature | Coolant (for inverter) temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - |
| Inverter Input Current | Inverter input current | Min.: -3276.8 A, Max.: 3276.7 A | - |
| Inverter Water Pump Duty | Inverter water pump motor driver request duty | Min.: 0%, Max.: 100% | - |
| Inverter Water Pump Revolution | Inverter water pump assembly speed | Min.: 0 rpm, Max.: 65535 rpm | - |
| Reactor Temperature | Reactor Temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - |
| Collinear Graphic Engine Revolution | Col-linear graphic engine revolution | Min.: 0 rpm, Max.: 65535 rpm | - |
| Motor Resolver After Offset | Motor resolver offset value | Min.: 0.000 deg, Max.: 358.593 deg | - |
| Generator Resolver After Offset | Generator resolver offset value | Min.: 0.000 deg, Max.: 358.593 deg | - |
| VL Voltage | High voltage before it is boosted | Min.: 0.0 V, Max.: 6553.5 V | - |
| VH Voltage | High voltage after it is boosted | Min.: 0.0 V, Max.: 6553.5 V | - |
| Boosting Converter PWM Duty | Boost converter PWM duty | Min.: 0%, Max.: 100% | - |
| Boosting Converter Control Mode | Boost converter control mode | Min.: 0, Max.: 255 | - |
| Boosting Converter Carrier Frequency | Boost converter signal carrier frequency | 9.55 kHz/9.13 kHz/8.71 kHz/8.29 kHz/7.87 kHz/7.45 kHz/4.8 kHz | - |
| Boosting Converter Shut Down Signal | Boost converter shutdown signal | Min.: 0, Max.: 255 | - |
| Generate Request Torque | Generator torque request value | Min.: -4096.000 Nm, Max.: 4095.875 Nm | - |
| Shift Position | Shift position | P/R/N/D/B | - |
| Motor Temperature | Motor temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - |
| Generator Temperature | Generator temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - |
| Short Wave Highest Value | Waveform voltage in abnormal insulation detection circuit in Battery ECU assembly | Min.: 0.00 V, Max.: 4.98 V | - |
| Fail Safe Mode | Fail safe mode | Min.: -128, Max.: 127 | - |
| Accelerator Position | Accelerator pedal opening angle | Min.: 0%, Max.: 100.0% | - |
| WIN Control Limit Power | Charge control wattage sent from Battery ECU assembly to Hybrid vehicle control ECU assembly | Min.: -327.68 kW, Max.: 327.67 kW | - |
| WOUT Control Limit Power | Discharge control wattage sent from Battery ECU assembly to Hybrid vehicle control ECU assembly | Min.: -327.68 kW, Max.: 327.67 kW | - |
| Engine Control Mode | Engine control mode | Stop, Stop Process, Startup Process, Running | - |
| Generator Inverter Temperature | Generator Inverter Temperature | Min.: 8°C (46.4°F), Max.: 150°C (302°F) | - |
| Emergency Shutdown Signal | Inverter emergency shutdown | ON or OFF | - |
| Ready ON Status | State of system (READY) | ON or OFF | - |
| SMR Status | SMR status | ON or OFF | - |
| Generator Inverter High Current (GFINV) | Generator inverter high current | ON or OFF | - |
| Generator Inverter Shut Down Status | Generator inverter shutdown status | ON or OFF | - |
| PTC Heater Activate Permission Status/Prohibition Signal (IDH) | PTC heater | ON or OFF | - |
| DC/DC Converter Terminate Signal | DC/DC converter stop request signal | ON or OFF | - |
| Motor Inverter High Current (MFINV) | Motor inverter high current | ON or OFF | - |
| Motor Inverter Shut Down Status | Motor inverter shutdown | ON or OFF | - |
| Inverter Input High Voltage (OVH) | Inverter input high voltage | ON or OFF | - |
| Boosting Converter Input High Current (CFINV) | Boost converter input high current | ON or OFF | - |
| Boosting Converter Shut Down Status | Boost converter shutdown | ON or OFF | - |
| Total Distance Traveled | Drive total distance | Min.: 0 km (0 mile), Max.: 16777215 km (10425361 mile) | - |
| Total Distance Traveled - Unit | Drive total distance unit | km or mile | - |