DTC Repair Priority And Inspection Parts
WARNING: This page is about a different variant/trim than selected.
- The diagnoses for each DTC of hybrid control system basically consist of the combination of each system inspection.
- If several DTCs are output, perform the diagnoses in order according to the priority, resulting in the possibility of more precise diagnoses.
DTC priority and inspection parts
DTC DESCRIPTION
| DTC No. | Diagnostic item | Priority | Inspection pattern | ||||
|---|---|---|---|---|---|---|---|
| 1 | 2 | 3 | 4 | 5 | |||
| Micro computer malfunction | Power supply system malfunction | Communication system malfunction | Sensor and actuator circuit malfunction | System malfunction | |||
| P034000 | CAMSHAFT POSITION SENSOR "A" CIRCUIT BANK 1 OR SINGLE SENSOR | - | - | - | ◦ | - | - |
| P034031 | CAMSHAFT POSITION SENSOR "A" CIRCUIT BANK 1 OR SINGLE SENSOR NO SIGNAL | - | - | - | ◦ | - | - |
| P062F44 | INTERNAL CONTROL MODULE EEPROM DATA MEMORY FAILURE | ◦ | - | - | - | - | - |
| P06B01C | GENERATOR CONTROL MODULE POSITION SENSOR REF POWER SOURCE CIRCUIT VOLTAGE OUT OF RANGE | - | ◦ | - | - | - | - |
| P06D61C | GENERATOR CONTROL MODULE OFFSET POWER CIRCUIT VOLTAGE OUT OF RANGE | - | ◦ | - | - | - | - |
| P0A0011 | MOTOR ELECTRONICS COOLANT TEMPERATURE SENSOR CIRCUIT SHORT TO GROUND | - | - | - | ◦ | - | - |
| P0A0015 | MOTOR ELECTRONICS COOLANT TEMPERATURE SENSOR CIRCUIT SHORT TO BATTERY OR OPEN | - | - | - | ◦ | - | - |
| P0A0812 | DC/DC CONVERTER STATUS CIRCUIT SHORT TO BATTERY | - | - | - | ◦ | - | A |
| P0A0814 | DC/DC CONVERTER STATUS CIRCUIT SHORT TO GROUND OR OPEN | - | - | - | ◦ | - | A |
| P0A1112 | DC/DC CONVERTER ENABLE CIRCUIT SHORT TO BATTERY | - | - | - | ◦ | - | A |
| P0A1114 | DC/DC CONVERTER ENABLE CIRCUIT SHORT TO GROUND OR OPEN | - | - | - | ◦ | - | A |
| P0A1A47 | GENERATOR CONTROL MODULE WATCHDOG/SAFETY MC FAILURE | ◦ | - | - | - | - | - |
| P0A1A49 | GENERATOR CONTROL MODULE INTERNAL ELECTRONIC FAILURE | ◦ | - | - | - | - | - |
| P0A1B1F | GENERATOR CONTROL MODULE CIRCUIT INTERMITTENT | ◦ | - | - | - | - | - |
| P0A3F16 | DRIVE MOTOR "A" POSITION SENSOR CIRCUIT VOLTAGE BELOW THRESHOLD | - | - | - | ◦ | - | G |
| P0A3F1F | DRIVE MOTOR "A" POSITION SENSOR CIRCUIT INTERMITTENT | - | - | - | ◦ | - | G |
| P0A3F21 | DRIVE MOTOR "A" POSITION SENSOR SIGNAL AMPLITUDE < MINIMUM | - | - | - | ◦ | - | G |
| P0A3F22 | DRIVE MOTOR "A" POSITION SENSOR SIGNAL AMPLITUDE>MAXIMUM | - | - | - | ◦ | - | G |
| P0A4B16 | GENERATOR POSITION SENSOR CIRCUIT VOLTAGE BELOW THRESHOLD | - | - | - | ◦ | - | I |
| P0A4B1F | GENERATOR POSITION SENSOR CIRCUIT INTERMITTENT | - | - | - | ◦ | - | I |
| P0A4B21 | GENERATOR POSITION SENSOR SIGNAL AMPLITUDE < MINIMUM | - | - | - | ◦ | - | I |
| P0A4B22 | GENERATOR POSITION SENSOR SIGNAL AMPLITUDE>MAXIMUM | - | - | - | ◦ | - | I |
| P0A6012 | DRIVE MOTOR "A" PHASE V CURRENT (HIGH RESOLUTION) CIRCUIT SHORT TO BATTERY | - | - | - | ◦ | - | A |
| P0A6014 | DRIVE MOTOR "A" PHASE V CURRENT (HIGH RESOLUTION) CIRCUIT SHORT TO GROUND OR OPEN | - | - | - | ◦ | - | A |
| P0A601C | DRIVE MOTOR "A" PHASE V CURRENT (HIGH RESOLUTION) CIRCUIT VOLTAGE OUT OF RANGE | - | - | - | ◦ | - | A |
| P0A601F | DRIVE MOTOR "A" PHASE V CURRENT (HIGH RESOLUTION) CIRCUIT INTERMITTENT | - | - | - | ◦ | - | A |
| P0A6312 | DRIVE MOTOR "A" PHASE W CURRENT (HIGH RESOLUTION) CIRCUIT SHORT TO BATTERY | - | - | - | ◦ | - | A |
| P0A6314 | DRIVE MOTOR "A" PHASE W CURRENT (HIGH RESOLUTION) CIRCUIT SHORT TO GROUND OR OPEN | - | - | - | ◦ | - | A |
| P0A631C | DRIVE MOTOR "A" PHASE W CURRENT (HIGH RESOLUTION) CIRCUIT VOLTAGE OUT OF RANGE | - | - | - | ◦ | - | A |
| P0A631F | DRIVE MOTOR "A" PHASE W CURRENT (HIGH RESOLUTION) CIRCUIT INTERMITTENT | - | - | - | ◦ | - | A |
| P0A7872 | DRIVE MOTOR "A" INVERTER ACTUATOR STUCK OPEN | - | - | - | - | ◦ | A |
| P0A7873 | DRIVE MOTOR "A" INVERTER ACTUATOR STUCK CLOSED | - | - | - | - | ◦ | - |
| P0A789E | DRIVE MOTOR "A" INVERTER STUCK ON | - | - | - | - | ◦ | E |
| P0A7A72 | GENERATOR INVERTER ACTUATOR STUCK OPEN | - | - | - | - | ◦ | A |
| P0A7A73 | GENERATOR INVERTER ACTUATOR STUCK CLOSED | - | - | - | - | ◦ | - |
| P0A7A9E | GENERATOR INVERTER STUCK ON | - | - | - | - | ◦ | E |
| P0A9000 | DRIVE MOTOR "A" PERFORMANCE | - | - | - | - | ◦ | H |
| P0A9200 | HYBRID GENERATOR PERFORMANCE | - | - | - | - | ◦ | J |
| P0A949E | DC/DC CONVERTER STUCK ON | - | - | - | - | ◦ | E |
| P0AED11 | DRIVE MOTOR INVERTER TEMPERATURE SENSOR "A" CIRCUIT SHORT TO GROUND | - | - | - | ◦ | - | - |
| P0AED15 | DRIVE MOTOR INVERTER TEMPERATURE SENSOR "A" CIRCUIT SHORT TO BATTERY OR OPEN | - | - | - | ◦ | - | - |
| P0AED1C | DRIVE MOTOR INVERTER TEMPERATURE SENSOR "A" CIRCUIT VOLTAGE OUT OF RANGE | - | - | - | ◦ | - | B |
| P0BCC11 | GENERATOR INVERTER TEMPERATURE SENSOR CIRCUIT SHORT TO GROUND | - | - | - | ◦ | - | - |
| P0BCC15 | GENERATOR INVERTER TEMPERATURE SENSOR CIRCUIT SHORT TO BATTERY OR OPEN | - | - | - | ◦ | - | - |
| P0BCC1C | GENERATOR INVERTER TEMPERATURE SENSOR CIRCUIT VOLTAGE OUT OF RANGE | - | - | - | ◦ | - | - |
| P0BE512 | DRIVE MOTOR "A" PHASE U CURRENT SENSOR CIRCUIT SHORT TO BATTERY | - | - | - | ◦ | - | A |
| P0BE514 | DRIVE MOTOR "A" PHASE U CURRENT SENSOR CIRCUIT SHORT TO GROUND OR OPEN | - | - | - | ◦ | - | A |
| P0BE51F | DRIVE MOTOR "A" PHASE U CURRENT SENSOR CIRCUIT INTERMITTENT | - | - | - | ◦ | - | A |
| P0BE528 | DRIVE MOTOR "A" PHASE U CURRENT SENSOR SIGNAL BIAS LEVEL OUT OF RANGE/ZERO ADJUSTMENT FAILURE | - | - | - | ◦ | - | A |
| P0BE912 | DRIVE MOTOR "A" PHASE V CURRENT SENSOR CIRCUIT SHORT TO BATTERY | - | - | - | ◦ | - | A |
| P0BE914 | DRIVE MOTOR "A" PHASE V CURRENT SENSOR CIRCUIT SHORT TO GROUND OR OPEN | - | - | - | ◦ | - | A |
| P0BE91F | DRIVE MOTOR "A" PHASE V CURRENT SENSOR CIRCUIT INTERMITTENT | - | - | - | ◦ | - | A |
| P0BE928 | DRIVE MOTOR "A" PHASE V CURRENT SENSOR SIGNAL BIAS LEVEL OUT OF RANGE/ZERO ADJUSTMENT FAILURE | - | - | - | ◦ | - | A |
| P0BED12 | DRIVE MOTOR "A" PHASE W CURRENT SENSOR CIRCUIT SHORT TO BATTERY | - | - | - | ◦ | - | A |
| P0BED14 | DRIVE MOTOR "A" PHASE W CURRENT SENSOR CIRCUIT SHORT TO GROUND OR OPEN | - | - | - | ◦ | - | A |
| P0BED1F | DRIVE MOTOR "A" PHASE W CURRENT SENSOR CIRCUIT INTERMITTENT | - | - | - | ◦ | - | A |
| P0BED28 | DRIVE MOTOR "A" PHASE W CURRENT SENSOR SIGNAL BIAS LEVEL OUT OF RANGE/ZERO ADJUSTMENT FAILURE | - | - | - | ◦ | - | A |
| P0BFD62 | DRIVE MOTOR "A" PHASE U-V-W CURRENT SENSOR SIGNAL COMPARE FAILURE | - | - | - | ◦ | - | K |
| P0BFF1D | DRIVE MOTOR "A" CIRCUIT CURRENT OUT OF RANGE | - | - | - | - | ◦ | M |
| P0C1900 | DRIVE MOTOR "A" EXECUTION TORQUE PERFORMANCE | - | - | - | - | ◦ | M |
| P0C3811 | DC/DC CONVERTER TEMPERATURE SENSOR "A" CIRCUIT SHORT TO GROUND | - | - | - | ◦ | - | - |
| P0C3815 | DC/DC CONVERTER TEMPERATURE SENSOR "A" CIRCUIT SHORT TO BATTERY OR OPEN | - | - | - | ◦ | - | - |
| P0C381C | DC/DC CONVERTER TEMPERATURE SENSOR "A" CIRCUIT VOLTAGE OUT OF RANGE | - | - | - | ◦ | - | B |
| P0C3D11 | DC/DC CONVERTER TEMPERATURE SENSOR "B" CIRCUIT SHORT TO GROUND | - | - | - | ◦ | - | - |
| P0C3D15 | DC/DC CONVERTER TEMPERATURE SENSOR "B" CIRCUIT SHORT TO BATTERY OR OPEN | - | - | - | ◦ | - | - |
| P0C3D1C | DC/DC CONVERTER TEMPERATURE SENSOR "B" CIRCUIT VOLTAGE OUT OF RANGE | - | - | - | ◦ | - | B |
| P0C5013 | DRIVE MOTOR "A" POSITION SENSOR CIRCUIT "A" CIRCUIT OPEN | - | - | - | ◦ | - | G |
| P0C5016 | DRIVE MOTOR "A" POSITION SENSOR CIRCUIT "A" CIRCUIT VOLTAGE BELOW THRESHOLD | - | - | - | ◦ | - | A |
| P0C5017 | DRIVE MOTOR "A" POSITION SENSOR CIRCUIT "A" CIRCUIT VOLTAGE ABOVE THRESHOLD | - | - | - | ◦ | - | A |
| P0C501F | DRIVE MOTOR "A" POSITION SENSOR CIRCUIT "A" CIRCUIT INTERMITTENT | - | - | - | ◦ | - | G |
| P0C5A13 | DRIVE MOTOR "A" POSITION SENSOR CIRCUIT "B" CIRCUIT OPEN | - | - | - | ◦ | - | G |
| P0C5A16 | DRIVE MOTOR "A" POSITION SENSOR CIRCUIT "B" CIRCUIT VOLTAGE BELOW THRESHOLD | - | - | - | ◦ | - | A |
| P0C5A17 | DRIVE MOTOR "A" POSITION SENSOR CIRCUIT "B" CIRCUIT VOLTAGE ABOVE THRESHOLD | - | - | - | ◦ | - | A |
| P0C5A1F | DRIVE MOTOR "A" POSITION SENSOR CIRCUIT "B" CIRCUIT INTERMITTENT | - | - | - | ◦ | - | G |
| P0C6413 | GENERATOR POSITION SENSOR CIRCUIT "A" CIRCUIT OPEN | - | - | - | ◦ | - | I |
| P0C6416 | GENERATOR POSITION SENSOR CIRCUIT "A" CIRCUIT VOLTAGE BELOW THRESHOLD | - | - | - | ◦ | - | A |
| P0C6417 | GENERATOR POSITION SENSOR CIRCUIT "A" CIRCUIT VOLTAGE ABOVE THRESHOLD | - | - | - | ◦ | - | A |
| P0C641F | GENERATOR POSITION SENSOR CIRCUIT "A" CIRCUIT INTERMITTENT | - | - | - | ◦ | - | I |
| P0C6913 | GENERATOR POSITION SENSOR CIRCUIT "B" CIRCUIT OPEN | - | - | - | ◦ | - | I |
| P0C6916 | GENERATOR POSITION SENSOR CIRCUIT "B" CIRCUIT VOLTAGE BELOW THRESHOLD | - | - | - | ◦ | - | A |
| P0C6917 | GENERATOR POSITION SENSOR CIRCUIT "B" CIRCUIT VOLTAGE ABOVE THRESHOLD | - | - | - | ◦ | - | A |
| P0C691F | GENERATOR POSITION SENSOR CIRCUIT "B" CIRCUIT INTERMITTENT | - | - | - | ◦ | - | I |
| P0C7917 | DRIVE MOTOR "A" INVERTER VOLTAGE SENSOR (VH) CIRCUIT VOLTAGE ABOVE THRESHOLD | - | - | - | - | ◦ | F |
| P0CA300 | DC/DC CONVERTER STEP UP VOLTAGE PERFORMANCE | - | - | - | - | ◦ | A |
| P0D2D16 | DRIVE MOTOR "A" INVERTER VOLTAGE SENSOR (VH) CIRCUIT VOLTAGE BELOW THRESHOLD | - | - | - | ◦ | - | - |
| P0D2D17 DRIVE MOTOR "A" INVERTER VOLTAGE SENSOR (VH) CIRCUIT VOLTAGE ABOVE THRESHOLD | - | - | - | ◦ | - | - | |
| P0D2D1F | DRIVE MOTOR "A" INVERTER VOLTAGE SENSOR (VH) CIRCUIT INTERMITTENT | - | - | - | ◦ | - | - |
| P0D3319 | DC/DC CONVERTER CIRCUIT CURRENT ABOVE THRESHOLD | - | - | - | - | ◦ | E |
| P0DFA62 | GENERATOR PHASE U-V-W CURRENT SENSOR SIGNAL COMPARE FAILURE | - | - | - | ◦ | - | J |
| P0E0012 | GENERATOR PHASE U CURRENT SENSOR CIRCUIT SHORT TO BATTERY | - | - | - | ◦ | - | A |
| P0E0014 | GENERATOR PHASE U CURRENT SENSOR CIRCUIT SHORT TO GROUND OR OPEN | - | - | - | ◦ | - | A |
| P0E001F | GENERATOR PHASE U CURRENT SENSOR CIRCUIT INTERMITTENT | - | - | - | ◦ | - | A |
| P0E0028 | GENERATOR PHASE U CURRENT SENSOR SIGNAL BIAS LEVEL OUT OF RANGE/ZERO ADJUSTMENT FAILURE | - | - | - | ◦ | - | A |
| P0E0412 | GENERATOR PHASE V CURRENT SENSOR CIRCUIT SHORT TO BATTERY | - | - | - | ◦ | - | A |
| P0E0414 | GENERATOR PHASE V CURRENT SENSOR CIRCUIT SHORT TO GROUND OR OPEN | - | - | - | ◦ | - | A |
| P0E041F | GENERATOR PHASE V CURRENT SENSOR CIRCUIT INTERMITTENT | - | - | - | ◦ | - | A |
| P0E0428 | GENERATOR PHASE V CURRENT SENSOR SIGNAL BIAS LEVEL OUT OF RANGE/ZERO ADJUSTMENT FAILURE | - | - | - | ◦ | - | A |
| P0E0812 | GENERATOR PHASE W CURRENT SENSOR CIRCUIT SHORT TO BATTERY | - | - | - | ◦ | - | A |
| P0E0814 | GENERATOR PHASE W CURRENT SENSOR CIRCUIT SHORT TO GROUND OR OPEN | - | - | - | ◦ | - | A |
| P0E081F | GENERATOR PHASE W CURRENT SENSOR CIRCUIT INTERMITTENT | - | - | - | ◦ | - | A |
| P0E0828 | GENERATOR PHASE W CURRENT SENSOR SIGNAL BIAS LEVEL OUT OF RANGE/ZERO ADJUSTMENT FAILURE | - | - | - | ◦ | - | A |
| P0E3116 | DC/DC CONVERTER VOLTAGE SENSOR "A" (VL) CIRCUIT VOLTAGE BELOW THRESHOLD | - | - | - | ◦ | - | - |
| P0E3117 | DC/DC CONVERTER VOLTAGE SENSOR "A" (VL) CIRCUIT VOLTAGE ABOVE THRESHOLD | - | - | - | ◦ | - | - |
| P0E311F | DC/DC CONVERTER VOLTAGE SENSOR "A" (VL) CIRCUIT INTERMITTENT | - | - | - | ◦ | - | - |
| P0E5111 | DC/DC CONVERTER CURRENT SENSOR CIRCUIT SHORT TO GROUND | - | - | - | ◦ | - | - |
| P0E5115 | DC/DC CONVERTER CURRENT SENSOR CIRCUIT SHORT TO BATTERY OR OPEN | - | - | - | ◦ | - | - |
| P0E511F | DC/DC CONVERTER CURRENT SENSOR CIRCUIT INTERMITTENT | - | - | - | ◦ | - | - |
| P0E5128 | DC/DC CONVERTER CURRENT SENSOR SIGNAL BIAS LEVEL OUT OF RANGE/ZERO ADJUSTMENT FAILURE | - | - | - | - | ◦ | A |
| P0E512A | DC/DC CONVERTER CURRENT SENSOR SIGNAL STUCK IN RANGE | - | - | - | ◦ | - | L |
| P0E5717 | DC/DC CONVERTER VOLTAGE SENSOR "A" (VL) CIRCUIT VOLTAGE ABOVE THRESHOLD | - | - | - | - | ◦ | F |
| P0E5811 | DC/DC CONVERTER TEMPERATURE SENSOR 2 CIRCUIT SHORT TO GROUND | - | - | - | ◦ | - | - |
| P0E5815 | DC/DC CONVERTER TEMPERATURE SENSOR 2 CIRCUIT SHORT TO BATTERY OR OPEN | - | - | - | ◦ | - | - |
| P0E581C | DC/DC CONVERTER TEMPERATURE SENSOR 2 CIRCUIT VOLTAGE OUT OF RANGE | - | - | - | ◦ | - | B |
| P0E7100 | GENERATOR EXECUTION TORQUE PERFORMANCE | - | - | - | - | ◦ | M |
| P155911 | REACTOR TEMPERATURE SENSOR CIRCUIT SHORT TO GROUND | - | - | - | ◦ | - | B |
| P155915 | REACTOR TEMPERATURE SENSOR CIRCUIT SHORT TO BATTERY OR OPEN | - | - | - | ◦ | - | B |
| P1C2A1C | GENERATOR A/D CONVERTER CIRCUIT CIRCUIT VOLTAGE OUT OF RANGE | ◦ | - | - | - | - | - |
| P1C2A49 | GENERATOR A/D CONVERTER CIRCUIT INTERNAL ELECTRONIC FAILURE | ◦ | - | - | - | - | - |
| P1C2B1C | DRIVE MOTOR "A" CONTROL MODULE A/D CONVERTER CIRCUIT VOLTAGE OUT OF RANGE | ◦ | - | - | - | - | - |
| P1C2B49 | DRIVE MOTOR "A" CONTROL MODULE A/D CONVERTER CIRCUIT INTERNAL ELECTRONIC FAILURE | ◦ | - | - | - | - | - |
| P1C2E46 | MOTOR GENERATOR ECU (EEPROM) CALIBRATION/PARAMETER MEMORY FAILURE | ◦ | - | - | - | - | - |
| P1C5D19 | DRIVE MOTOR "A" INVERTER CIRCUIT CURRENT ABOVE THRESHOLD | - | - | - | - | ◦ | E |
| P1C5F19 | GENERATOR INVERTER CIRCUIT CURRENT ABOVE THRESHOLD | - | - | - | - | ◦ | E |
| P1C601F | GENERATOR CONTROL MODULE POSITION SENSOR REF POWER SOURCE CIRCUIT INTERMITTENT | - | ◦ | - | - | - | - |
| P1C621F | GENERATOR CONTROL MODULE OFFSET POWER CIRCUIT INTERMITTENT | - | ◦ | - | - | - | - |
| P1C641F | GENERATOR CONTROL MODULE CIRCUIT INTERMITTENT | ◦ | - | - | - | - | C |
| P1C651F | GENERATOR CONTROL MODULE CIRCUIT INTERMITTENT | ◦ | - | - | - | - | C |
| P1C671F | DRIVE MOTOR "A" PHASE U-V-W CURRENT SENSOR CIRCUIT INTERMITTENT | - | - | - | ◦ | - | K |
| P1C691F | GENERATOR PHASE U-V-W CURRENT SENSOR CIRCUIT INTERMITTENT | - | - | - | ◦ | - | J |
| P1CA062 | MOTOR ELECTRONICS COOLANT TEMPERATURE SENSOR/REACTOR TEMPERATURE SENSOR SIGNAL COMPARE FAILURE | - | - | - | ◦ | - | - |
| P1CA51D | HYBRID GENERATOR CIRCUIT CURRENT OUT OF RANGE | - | - | - | - | ◦ | M |
| P1CAC49 | GENERATOR POSITION SENSOR INTERNAL ELECTRONIC FAILURE | - | - | - | ◦ | - | C |
| P1CAD49 | DRIVE MOTOR "A" POSITION SENSOR INTERNAL ELECTRONIC FAILURE | - | - | - | ◦ | - | C |
| P1CAF38 | GENERATOR POSITION SENSOR REF SIGNAL CYCLE MALFUNCTION SIGNAL FREQUENCY INCORRECT | - | - | - | ◦ | - | C |
| P1CB038 | DRIVE MOTOR "A" POSITION SENSOR REF SIGNAL FREQUENCY INCORRECT | - | - | - | ◦ | - | C |
| P1CB59E | DC/DC CONVERTER VOLTAGE SENSOR "A" (VL) STUCK ON | - | - | - | - | ◦ | A |
| P1CB69E | DRIVE MOTOR "A" INVERTER VOLTAGE SENSOR (VH) STUCK ON | - | - | - | - | ◦ | A |
| P1CCC96 | DC/DC CONVERTER ENABLE COMPONENT INTERNAL FAILURE | - | - | - | - | ◦ | - |
| P1CFF62 | HYBRID/EV BATTERY CURRENT/DC/DC CONVERTER CURRENT SIGNAL COMPARE FAILURE | - | - | - | - | ◦ | A |
| P31241F | LOST COMMUNICATION BETWEEN DRIVE MOTOR "A" AND HV ECU CIRCUIT INTERMITTENT | - | - | ◦ | - | - | - |
| P312487 | LOST COMMUNICATION BETWEEN DRIVE MOTOR "A" AND HV ECU MISSING MESSAGE | - | - | ◦ | - | - | - |
| P313383 | COMMUNICATION ERROR FROM GENERATOR TO DRIVE MOTOR "A" VALUE OF SIGNAL PROTECTION CALCULATION INCORRECT | ◦ | - | - | - | - | - |
| P313386 | COMMUNICATION ERROR FROM GENERATOR TO DRIVE MOTOR "A" SIGNAL INVALID | ◦ | - | - | - | - | - |
| P313387 | COMMUNICATION ERROR FROM GENERATOR TO DRIVE MOTOR "A" MISSING MESSAGE | ◦ | - | - | - | - | - |
| P313483 | COMMUNICATION ERROR FROM DRIVE MOTOR "A" TO GENERATOR VALUE OF SIGNAL PROTECTION CALCULATION INCORRECT | ◦ | - | - | - | - | - |
| P313486 | COMMUNICATION ERROR FROM DRIVE MOTOR "A" TO GENERATOR SIGNAL INVALID | ◦ | - | - | - | - | - |
| P313487 | COMMUNICATION ERROR FROM DRIVE MOTOR "A" TO GENERATOR MISSING MESSAGE | ◦ | - | - | - | - | - |
| P314F1F | DC/DC CONVERTER VOLTAGE SENSOR "A" (VL) CIRCUIT INTERMITTENT | - | - | - | - | ◦ | F |
| P31531D | DC/DC CONVERTER CURRENT SENSOR CIRCUIT CURRENT OUT OF RANGE | - | - | - | - | ◦ | F |
| U010087 | LOST COMMUNICATION WITH ECM/PCM "A" MISSING MESSAGE | - | - | ◦ | - | - | - |
| U029387 | LOST COMMUNICATION WITH HYBRID POWERTRAIN CONTROL MODULE MISSING MESSAGE | - | - | ◦ | - | - | - |
| U117087 | LOST COMMUNICATION WITH BRAKE SYSTEM CONTROL MODULE (CH2) MISSING MESSAGE | - | - | ◦ | - | - | - |
NOTE:
The following "Examples of several DTCs output" must be used as reference of abnormal conditions. Therefore, do not use the examples when actually performing the check.
Examples of several DTCs output
- The power supply in microcomputer is reduced while driving.
- DTCs are detected and the vehicle behavior is as follows.
Detected DTCs
- DTC P060B1C (HYBRID/EV POWERTRAIN CONTROL MODULE A/D PROCESSING VOLTAGE OUT OF RANGE). Microcomputer malfunction*
- DTC P0C5016 (DRIVE MOTOR "A" POSITION SENSOR CIRCUIT "A" CIRCUIT VOLTAGE BELOW THRESHOLD)... Sensor and actuator circuit malfunction*
- DTC P0A3F16 (DRIVE MOTOR "A" POSITION SENSOR CIRCUIT VOLTAGE BELOW THRESHOLD)... Sensor and actuator circuit malfunction*
- DTC P1CAD49 (DRIVE MOTOR "A" POSITION SENSOR INTERNAL ELECTRONIC FAILURE)... Sensor and actuator circuit malfunction* DTC P1CAC49 (GENERATOR POSITION SENSOR INTERNAL ELECTRONIC FAILURE)... Sensor and actuator circuit
*: Check the priority level using "DTC priority" table described above.
Vehicle behavior
Hybrid system stopped
- The inspection priority is as follows: "Microcomputer system → Power supply system → Communication system → Sensor/actuator system → System". Therefore, check the repair procedure of DTC P060B1C.
- Replace the Hybrid vehicle control ECU assembly according to the repair procedure. Repair finished.
This allows you to identify the defective area without performing unnecessary checks.