High Pressure Solenoid Valve

WARNING: This page is about a different variant/trim than selected.
  1. Visually check the HI solenoid valve for cracks or other damage, and replace as necessary.
  2. Check the operation of the HI solenoid valve when battery voltage is applied between the connector terminals.
    G13234303Courtesy of SUBARU OF AMERICA, INC.
    Terminal No. Inspection conditions Specification
    2 (+) - 1 (-) Apply battery voltage and discharge compressed air in the direction of the arrow. Must not discharge.
  3. If the check results show that it does not operate normally, replace the HI solenoid valve.