LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2020 >> Crosstrek Base, Automatic CVT Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 11 (HVAC System (Heater, Ventilator And A/C) (HEV)) >> General Description >> Specification >> Heater System

Heater System

WARNING: This page is about a different variant/trim than selected.
Item Specifications Condition
Heating capacity 5 kW (4, 299 kcal/h, 17, 059 BTU/h) or more
  • Air flow control dial: FOOT
  • Temperature control dial: HI (MAX HOT)
  • Temperature difference between hot water and inlet air: 65°C (149°F)
  • Hot water flow rate: 360 L (95.1 US gal, 79.2 Imp gal)/h
Air flow rate 300 m3 (10, 596 cu ft)/h or more FOOT mode (FRESH), MAX HOT at 12.5 V
Max air flow rate 480 m3 (16, 954 cu ft)/h or more
  • Temperature control dial: LO (MAX COOL)
  • Fan dial: HI (MAX)
  • FRESH/RECIRC switch: RECIRC
Heater core Size (width x height x thickness) 263.9 x 120 x 27 mm (10.39 x 4.72 x 1.06 in) -
Blower motor Motor type Magnet -
Power consumption 260 W or less 12 V
Fan type Sirocco fan -
Size (diameter x height) 137 x 60 mm (5.39 x 2.36 in) -
PTC heater Size (width x height x thickness) 267.5 x 84 x 12 mm (10.53 x 3.31 x 0.47 in) -