Check Actuator
WARNING: This page is about a different variant/trim than selected.
- Check the actuator operation when battery voltage is applied between the connector terminals.CAUTION: Disconnect the battery immediately after the actuator stops operation. Otherwise, the motor may be damaged.
Terminal No. Inspection conditions Operating position 4 (+) - 5 (-) Apply battery voltage. FRESH 5 (+) - 4 (-) RECIRC - Measure the resistance between connector terminals.
Preparation tool:
Circuit tester
Terminal No. Inspection conditions Standard 1 - 3 Always 4.2 - 7.8 Ω - Connect the connector, turn the ignition switch to ON, and check the voltage between actuator terminals.
Terminal No. Inspection conditions Standard 2 (+) - 1 (-) FRESH Approximately 1.9 V RECIRC Approximately 4.5 V - If it is found defective as a result of inspection, replace the motor - actuator intake.