Heater Valve
WARNING: This page is about a different variant/trim than selected.
CAUTION:
Check that the DTC B1452 (heating expansion valve circuit) is not displayed.
- Visually check that there is no dirt or damage on the expansion valve - heater assembly. Clean or replace as necessary.
- Attach the manifold gauge set. Ref. to AIR CONDITIONER (HEV)>REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET>PROCEDURE .
Preparation tool:
Manifold gauge set
- Using the Subaru Select Monitor, select [Heating electric expansion valve] under [Air Conditioner] in the active test list. Ref. to AIR CONDITIONER (DIAGNOSTICS) (HEV)>ACTIVE TEST .
- Set the vehicle to the following conditions.
Item Condition READY ON (engine stopped) Temperature control switch HI (MAX HOT) Fan dial HI (MAX) Ambient temperature 10 - 25°C (50 - 77°F) Engine coolant temperature 40°C (104°F) or less A/C switch OFF Driving cycle status (Confirm on Data Monitor.) Heating - Manipulate the active test input value, and check whether the manifold gauge value changes.NOTE: Check with active test input values in the range of 5 - 100%.
- If the check results show that the value does not change, replace the expansion valve - heater assembly.