DTC B14E5: Mode Door Actuator Stepping Motor Circuit Open

DTC detecting condition: 

Open circuit in the mode door actuator stepping motor circuit is detected for 3 seconds or more.

Trouble symptom: 

Vent does not change.

Wiring diagram: 

Air conditioning system Refer to WIRING SYSTEM>AIR CONDITIONING SYSTEM>WIRING DIAGRAM .

G12454225Courtesy of SUBARU OF AMERICA, INC.
  1. CHECK CONNECTOR. 
    1. Check the condition of connector connection.
    2. Read the DTC using Subaru Select Monitor. Refer to HVAC SYSTEM (AUTO A/C) (DIAGNOSTICS)>READ DIAGNOSTIC TROUBLE CODE (DTC) .

    Is DTC B14E5 displayed?

    Yes:  Go to  2.

    No  Even if DTC is displayed, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.

    NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
  2. CHECK ACTUATOR. 
    1. Turn the ignition switch to OFF.
    2. Disconnect the mode door actuator connector.
    3. Turn the ignition switch to ON.
    4. Measure the voltage between the mode door actuator connector terminal and chassis ground.

    Connector & terminal 

    (B77) No. 3 (+) - Chassis ground (-):

    Is the voltage approx. 10 V or more?

    Yes:  Go to  3.

    No  Check the DC power supply circuit.

  3. CHECK MODE DOOR ACTUATOR. 
    1. Turn the ignition switch to OFF.
    2. Measure the internal resistance of the mode door actuator using a tester.

    Terminals 

    Mode door actuator

    No. 3 - No. 1:

    No. 3 - No. 2:

    No. 3 - No. 5:

    No. 3 - No. 6:

    Is the resistance 80 - 100 Ω?

    Yes:  Go to  4.

    No  Replace the actuator. Refer to HVAC SYSTEM (HEATER, VENTILATOR AND A/C)>MODE DOOR ACTUATOR>REMOVAL .

  4. CHECK HARNESS BETWEEN A/C CONTROL PANEL AND MODE DOOR ACTUATOR (OPEN). 
    1. Disconnect the A/C control panel connector.
    2. Measure the resistance between A/C control panel and mode door actuator connector.

    Connector & terminal 

    (B77) No. 1 - (i88) No. 4:

    (B77) No. 2 - (i88) No. 3:

    (B77) No. 5 - (i88) No. 2:

    (B77) No. 6 - (i88) No. 1:

    Is there continuity?

    Yes  Replace the A/C control panel. Refer to HVAC SYSTEM (HEATER, VENTILATOR AND A/C)>CONTROL PANEL>REMOVAL .

    No  Repair or replace the open circuit of harness.