Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
Judge as NG when Monitor A1 and Monitor B1 are both NG, and when either is OK, judge as OK.
Monitor A1
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Diagnostic value 1 (DV1) | > Map |
MAP SPECIFICATION (CVT MODEL)
| Charging efficiency (air mass %) | |||||||
|---|---|---|---|---|---|---|---|
| 70 | 80 | 90 | 100 | 110 | 120 | ||
| Engine speed (rpm) | 1500 | 0.002 | 0.002 | 0.003 | 0.004 | 0.005 | 0.006 |
| 2000 | 0.002 | 0.002 | 0.003 | 0.004 | 0.009 | 0.013 | |
| 2500 | 0.002 | 0.002 | 0.006 | 0.012 | 0.018 | 0.022 | |
| 3000 | 0.004 | 0.009 | 0.016 | 0.022 | 0.027 | 0.031 | |
| 3500 | 0.005 | 0.009 | 0.018 | 0.023 | 0.028 | 0.032 | |
| 4000 | 0.015 | 0.018 | 0.029 | 0.033 | 0.036 | 0.041 | |
MAP SPECIFICATION (MT MODEL)
| Charging efficiency (air mass %) | |||||||
|---|---|---|---|---|---|---|---|
| 70 | 80 | 90 | 100 | 110 | 120 | ||
| Engine speed (rpm) | 1500 | 0.001 | 0.001 | 0.002 | 0.003 | 0.004 | 0.005 |
| 2000 | 0.001 | 0.001 | 0.002 | 0.003 | 0.007 | 0.010 | |
| 2500 | 0.002 | 0.002 | 0.005 | 0.009 | 0.014 | 0.018 | |
| 3000 | 0.002 | 0.003 | 0.006 | 0.015 | 0.019 | 0.024 | |
| 3500 | 0.002 | 0.004 | 0.008 | 0.015 | 0.019 | 0.024 | |
| 4000 | 0.003 | 0.006 | 0.008 | 0.015 | 0.019 | 0.024 | |
Time needed for diagnosis: 10 seconds
Monitor B1
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Diagnostic Value2 (DV2) | > 17 count |
Time needed for diagnosis: 1000 engine revs.
Malfunction indicator light illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.