If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE SPECIFICATION
| Malfunction | Criteria Threshold Value | ||
|---|---|---|---|
| ABS (1): Target line pressure - Measured line pressure | ≥ 500 kPa | ||
|
|||
Time needed for diagnosis: 5 seconds
Malfunction indicator light illumination: Illuminates as soon as a malfunction occurs.