Execution Condition
WARNING: This page is about a different variant/trim than selected.
| Secondary parameters |
Execution condition |
| Battery voltage |
≥ 10.9 V |
| Barometric pressure |
≥ 75 kPa (562.6 mmHg, 22.2 inHg) |
| Operation time of main feedback |
≥ 5 s |
| Engine speed |
≥ 1000 rpm |
| Amount of intake air |
≥ 10 g/s (0.35 oz/s) |