  1. Set the water pipe assembly RH on the engine, and connect the water pipe hose RH (B) to the oil pan upper.
  2. Install the bolt (A) which secures the water pipe assembly RH to the cylinder head RH.

    Tightening torque: 

    6.4 N.m (0.7 kgf-m, 4.7 ft-lb)

    G09480755Courtesy of SUBARU OF AMERICA, INC.
  3. Connect the water hose (A) to the water pipe assembly RH, and install the bolt (B) which secures the water pipe assembly RH to the cam carrier RH.

    Tightening torque: 

    6.4 N.m (0.7 kgf-m, 4.7 ft-lb)

    G09476398Courtesy of SUBARU OF AMERICA, INC.
  4. Install the front exhaust pipe. Refer to EXHAUST (EXCEPT FOR STI)>FRONT EXHAUST PIPE>INSTALLATION .
  5. Install the oil pipe assembly. Refer to LUBRICATION (EXCEPT FOR STI)>OIL PIPE>INSTALLATION>OIL PIPE ASSY .
  6. Connect the ground terminal to battery sensor. Refer to NOTE>NOTE>BATTERY .
  7. Fill engine coolant. Refer to COOLING (EXCEPT FOR STI)>ENGINE COOLANT>REPLACEMENT>FILLING OF ENGINE COOLANT .