Combination Meter System: Inspection: Switch
Illumination intensity does not change even when the illumination control switch is operated .
- CHECK CURRENT DATA
.
Display the data of «Bright switch input state» and «Illumination control switch input state» using the Subaru Select Monitor.
NOTE: For detailed operation procedures, refer to "Application help".Do the display switch between OFF ←→ ON and the value range from 0 to 100 when the bright switch and illumination control switch are operated?
Yes: Replace the combination meter.
No: Go to 2 .
- CHECK ILLUMINATION CONTROL SWITCH UNIT
.
Check the illumination control switch. Ref. to INSTRUMENTATION/DRIVER INFO>Switches and Harness>INSPECTION>ILLUMINATION CONTROL SWITCH .
Is the switch normal?
Yes: Go to 3 .
No: Replace the illumination control switch.
- CHECK HARNESS
.
- Disconnect the connectors of combination meter assembly and illumination control switch.
- Measure the resistance between the combination meter assembly and the illumination control switch.
Connector & terminal
(i10) No. 29 - (i79) No. 6:
(i10) No. 30 - (i79) No. 5:
(i10) No. 31 - (i79) No. 4:
(i10) No. 32 - (i79) No. 1:
Is the resistance less than 1 Ω?
Yes: Replace the combination meter.
No: Repair or replace the harness.