Floor Shift, Shift Lever ASSY: Adjustment
WARNING: This page is about a different variant/trim than selected.
- Reverse check adjustment
- Loosen the 4 flange bolts on the stopper.
- Shift the lever CP to the 2nd.
- Insert a shim that is 1.0 mm {0.0394 in} in thickness between the detent and the stopper, and push the stopper to the detent.STANDARD VALUE SPECIFICATION
Part Dimension a 1.0mm {0.0394in} - Tighten the 4 flange bolts on the stopper.
Standard value: T=7.5N.m {77kgf.cm} {5.5ft.lbf}
- Check that shift operation of 1st-2nd can be performed.
- If shift operation of 1st-2nd cannot be performed in the above check, perform the steps (1) to (4) with a shim that is 0.2 mm {0.0079 in} thinner.
- Check that shift operation of 1st-2nd can be performed.
- After the completion of reverse check adjustment, apply NIG-TIGHT LYW No. 2 or equivalent to the detent and the stopper.