LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2019 >> BRZ Limited, Automatic Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 1 (Manual Transaxle & Differential) >> Back-Up Light Switch >> Unit Inspection

Unit Inspection

WARNING: This page is about a different variant/trim than selected.
G12588007Courtesy of SUBARU OF AMERICA, INC.
  1. Check of back-up light switch ASSY
    1. Measure the resistance between the terminals.
      STANDARD VALUE RESISTANCE SPECIFICATION

      Inspection terminals Inspection conditions Standard value
      1 - 2 When switch is pressed in Less than 1 Ω
      When switch is not pressed in 1 MΩ or more

      If the resistance is not within the normal value, replace the back-up light switch ASSY.