PCV Valve (FA20): Installation
- Installation of PCV valve
- Apply THREE BOND 1324 to the PCV valve.
- Install the PCV valve to the cylinder head RH.
Standard value: T=23N.m {235kgf.cm} {17.0ft.lbf}
- Connect the ventilation hose to the PCV valve.
- Installation of intake manifold (Refer to INSTALLATION )