Inspection steps
- Checking diagnostic codes
- Check DTC using SSM4. (Refer to
CHECKING/CLEARING DIAGNOSTIC CODES )
Result
RESULT DESCRIPTIONResult Go to DTC output B2312. A DTC output B2315. B - Go to next step
- Go to Step 2.
Replacement of the power window regulator master switch ASSY (Refer to POWER WINDOW REGULATOR MASTER SWITCH ASSY )
- Check DTC using SSM4. (Refer to
CHECKING/CLEARING DIAGNOSTIC CODES )
- Reading of SSM4 data
- Using the SSM4, follow the display and read the [Data monitor]. (Refer to
DATA MONITOR/ACTIVE TEST )
Criteria: The normal value on the [Data monitor] is displayed properly.
SSM4 screen: [Each System] → [Power Window] → [Data monitor]
Item name Description/display range Normal value Remarks [Passenger seat AUTO SW state] Operation signal of switch AUTO for the passenger's seat/Display range: ON-OFF ON: AUTO switch is in operation.
OFF: Neutral- [Passenger seat MANUAL UP SW state] Operation signal of switch UP for the passenger's seat/Display range: ON-OFF ON: UP switch is in operation.
OFF: Neutral- [Passenger seat MANUAL DOWN SW state] Operation signal of switch DOWN for the passenger's seat/Display range: ON-OFF ON: DOWN switch is in operation.
OFF: Neutral- OK: Go to next step
NG: Replacement of the power window regulator switch ASSY (Refer to POWER WINDOW REGULATOR SWITCH ASSY (INSTALLED TO THE FRONT SIDE) )
- Using the SSM4, follow the display and read the [Data monitor]. (Refer to
DATA MONITOR/ACTIVE TEST )
- Inspection of the wire harness and connector (power window regulator master switch ASSY - power window regulator switch ASSY)
- Disconnect the connector E8 of power window regulator master switch ASSY.
- Disconnect the connector F6 of power window regulator switch ASSY LH.
- Measure the resistance between the terminals.
Resistance (open circuit check)
STANDARD VALUE SPECIFICATIONInspection terminals (Terminal symbol) Inspection conditions Standard value E8-2 (UART) - F6-2 (UART) Always Less than 1 Ω Resistance (short circuit check)
STANDARD VALUE SPECIFICATIONInspection terminals (Terminal symbol) Inspection conditions Standard value E8-2 (UART) - chassis ground Always 10 kΩ or more OK: Go to next step
NG: Repair or replacement of wiring harness or connector
Replacement of the power window regulator master switch ASSY (Refer to POWER WINDOW REGULATOR SWITCH ASSY (INSTALLED TO THE FRONT SIDE) )