- Disconnect the ground cable from battery and wait for at least 60 seconds before starting work. Ref. to NOTE>BATTERY
NOTE:
For model with battery sensor, disconnect the ground terminal from battery sensor.
- Remove the clips, and remove the cover - instrument panel side LH.
NOTE:
Using a plastic remover, open the cover - instrument panel side LH.
- Remove the cover assembly - instrument panel LWR driver INN and OUT.
CAUTION:
When removing the cover assembly - instrument panel LWR driver, be sure to pull it toward you. If attempting to remove by turning it upward, the claws may be damaged.
- Remove the screws and release the clips and claws.
- Disconnect the harness connectors, and remove the cover assembly - instrument panel LWR driver INN and OUT.