Illumination Control Switch
- Measure the resistance between connector terminals.
Preparation Tool:
Circuit tester
TERMINAL NO. INSPECTION CONDITIONS STANDARD 1 - 6 Bright switch OFF 10 kΩ or more Bright switch ON Less than 1 Ω 4 - 6 Always Approx. 4, 710 Ω 5 - 6 Illumination control switch upward fully open Approx. 510 Ω Illumination control switch downward fully open Approx. 4, 610 Ω - Apply Battery Voltage between the connector terminals to Check Lighting Condition of Illumination inside the Switch.SWITCH TERMINAL INSPECTION SPECIFICATION
Terminal No. Inspection Conditions Specification 2 (+) - 3(-) Apply Battery Voltage. Light ON - Replace the Illumination Control Switch if it is found defective.