Meter pointer operation check
In meter pointer operation check, the meter operation, warning/indicator light, illumination and TFT are checked.
- After a buzzer sounds for 0.5 seconds and "STEP1" is displayed on TFT, the meter pointer operation check mode is initiated.
Time
(sec)Meter indicator TFT display, illumination Warning/indicator light 6 MIN indication
↓
MAX indicationILL1 (Min. brightness)
↓(3)
ILL6 (Max. brightness)(1), (2) 6 MAX indication
↓
MIN indicationILL6 (Max. brightness)
↓(3)
ILL1 (Min. brightness)(1) Warning lights and indicator lights controlled by the meter drive circuit are illuminated. Ref. to INSTRUMENTATION/DRIVER INFO>General Description>SPECIFICATION . (2) Warning lights and indicator lights controlled by other module are turned on/off according to the module control. Ref. to INSTRUMENTATION/DRIVER INFO>General Description>SPECIFICATION . (3) Displays each level for one second.