DTC B1016 Shift Lock Circuit
DTC DETECTING CONDITION:
Shift lock circuit is open, or shorted to power or ground.
TROUBLE SYMPTOM:
Shift lock does not be released or remain locked.
WIRING DIAGRAM:
Shift lock control system <Ref. to WIRING DIAGRAM , Shift Lock Control System.>
| Step | Check | Yes | No |
|---|---|---|---|
1 CHECK DTC.
|
Is DTC B1016 displayed? (Current malfunction) | Go to step 6 . | Go to step 2 . |
2 CHECK DTC.
|
Is DTC B1016 displayed? (Current malfunction) | Go to step 3 . | Go to step 7 . |
3 CHECK HARNESS (OPEN CIRCUIT).
|
Is the resistance less than 10 Ω? | Go to step 4 . | Repair or replace the open circuit of harness. |
| 4 CHECK SHIFT LOCK SOLENOID. Using a tester, measure the resistance between shift lock solenoid terminals. Terminals Shift lock solenoid No. 4 - No. 3: |
Is the resistance between 27 - 31 Ω? | Go to step 5 . | Replace the shift lock solenoid. <Ref. to REMOVAL , AT Shift Lock Solenoid and "P" Range Switch.> |
| 5 CHECK SHIFT LOCK SOLENOID. Connect the battery terminal to shift lock solenoid. Terminals Shift lock solenoid No. 3 - Positive terminal: No. 4 - Ground terminal: |
Does the shift lock solenoid operate and then release the lock? | Go to step 6 . | Replace the shift lock solenoid. <Ref. to REMOVAL , AT Shift Lock Solenoid and "P" Range Switch.> |
| 6 CHECK HARNESS (OPEN CIRCUIT). Use a tester to measure the resistance between harness terminals. Connector & terminal (B116) No. 3 - (B281) No. 5:
NOTE:
If body integrated unit and shift lock connector are not disconnected, disconnect them first and then perform measurement.
|
Is the resistance less than 10 Ω? | Replace the body integrated unit. <Ref. to Body Integrated Unit .> | Repair or replace the open circuit of harness. |
7 CHECK DTC.
|
Is DTC B1016 displayed? (Current malfunction) | Go to step 8 . | Go to step 9 . |
8 CHECK DTC.
|
Is DTC B1016 displayed? (Current malfunction) | Go to step 4 . | Go to step 9 . |
9 CHECK CONNECTOR.
|
Is there poor contact of connector terminal? | Repair or replace the poor contact of terminal. | Even if DTC is displayed, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.
NOTE:
In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
|