DTC B1015 Key Interlock Circuit
DTC DETECTING CONDITION:
Short to ground in key interlock circuit
TROUBLE SYMPTOM:
Key interlock does not keep lock condition.
WIRING DIAGRAM:
Shift lock control system <Ref. to WIRING DIAGRAM , Shift Lock Control System.>
| Step | Check | Yes | No |
|---|---|---|---|
1 CHECK DTC.
|
Is DTC B1015 displayed? (Current malfunction) | Go to step 2 . | Go to step 8 . |
2 CHECK DTC.
|
Is DTC B1015 displayed? (Current malfunction) | Go to step 3 . | Go to step 8 . |
3 CHECK KEY ACTUATOR.
Terminals Key actuator No. 1 - No. 2: |
Is the resistance 103 - 115 Ω? | Go to step 4 . | Replace the key actuator. <Ref. to Key Lock Cylinders .> |
| 4 CHECK KEY ACTUATOR. Connect the battery terminals to the key actuator. Terminals Key actuator No. 1 - Positive terminal: No. 2 - Ground terminal: |
Is the actuator activated and then key locked? | Go to step 5 . | Replace the key actuator. <Ref. to Key Lock Cylinders .> |
5 CHECK HARNESS.
|
Is the resistance less than 10 Ω? | Go to step 6 . | Repair or replace the open circuit of harness. |
| 6 CHECK HARNESS (GROUND SHORT CIRCUIT). Measure the resistance between body integrated unit and chassis ground using tester. Connector & terminal (B281) No. 4 - Chassis ground: |
Is the resistance 1 MΩ or more? | Go to step 7 . | Repair or replace the short circuit of the harness. |
7 CHECK HARNESS.
|
Is the voltage 6 V or more? | Go to step 8 . | Replace the body integrated unit. <Ref. to Body Integrated Unit .> |
8 CHECK CONNECTOR.
|
Is there poor contact at disconnected connector terminal? | Repair the terminal where poor contact exists, or replace harness. | Even if DTC is displayed, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.
NOTE:
In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
|