LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2017 >> Legacy 3.6R Limited >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 9 (Engine Cooling System (H4DO)) >> Thermostat >> Inspection

Section 9 (Engine Cooling System (H4DO)): Thermostat: Inspection

WARNING: This page is about a different variant/trim than selected.
  1. Check that the thermostat does not have deformation, cracks or damage.
  2. Check that the thermostat valve closes completely at an ambient temperature.
  3. Immerse the thermostat and a thermometer in water. Raise water temperature gradually, and check the temperature and valve lift when the valve begins to open and when the valve is fully opened. Replace the thermostat if faulty.
    NOTE:
    • During the test, agitate the water for even temperature distribution.
    • Leave the thermostat in the boiling water for five minutes or more before measuring the valve lift.
    • Hold the thermostat with a wire or the like to avoid contacting with container bottom.

    Starting temperature to open: 

    Engine side 

    90 - 94°C (194 - 201°F) 

    CVTF cooler (with warmer feature) side (CVT model) 

    48 - 52°C (118 - 126°F) 

    Full open temperature: 

    Engine side 

    100°C (212°F) 

    CVTF cooler (with warmer feature) side (CVT model) 

    63°C (145°F) 

    Total valve lift: 

    Engine side 

    8.0 mm (0.315 in) or more 

    CVTF cooler (with warmer feature) side (CVT model) 

    6.0 mm (0.236 in) or more 

    Fig 1: Immersing Thermostat And Thermometer In Water
    G11566798Courtesy of SUBARU OF AMERICA, INC.